• 文献检索
  • 文档翻译
  • 深度研究
  • 学术资讯
  • Suppr Zotero 插件Zotero 插件
  • 邀请有礼
  • 套餐&价格
  • 历史记录
应用&插件
Suppr Zotero 插件Zotero 插件浏览器插件Mac 客户端Windows 客户端微信小程序
定价
高级版会员购买积分包购买API积分包
服务
文献检索文档翻译深度研究API 文档MCP 服务
关于我们
关于 Suppr公司介绍联系我们用户协议隐私条款
关注我们

Suppr 超能文献

核心技术专利:CN118964589B侵权必究
粤ICP备2023148730 号-1Suppr @ 2026

文献检索

告别复杂PubMed语法,用中文像聊天一样搜索,搜遍4000万医学文献。AI智能推荐,让科研检索更轻松。

立即免费搜索

文件翻译

保留排版,准确专业,支持PDF/Word/PPT等文件格式,支持 12+语言互译。

免费翻译文档

深度研究

AI帮你快速写综述,25分钟生成高质量综述,智能提取关键信息,辅助科研写作。

立即免费体验

Ensuring catheter-tissue contact with intracardiac echocardiography during pulsed-field ablation improves procedure outcome in patients with atrial fibrillation.

作者信息

Mohanty Sanghamitra, Casella Michela, Doty Brandon, Schiavone Marco, Gabrah Kirollos, Valeri Yari, Torlapati Prem Geeta, La Fazia Vincenzo Mirco, Gianni Carola, Al-Ahmad Amin, Burkhardt John D, Gallinghouse G J, Horton Rodney, Allison John, Bode Weeranun, Sharma Rashi, Dello Russo Antonio, Tondo Claudio, Nair Devi G, Natale Andrea

机构信息

Texas Cardiac Arrhythmia Institute, St. David's Medical Center, Austin, Texas.

Department of Electrophysiology, Ospedali Riuniti Hospital, Ancona, Italy.

出版信息

Heart Rhythm. 2025 Oct;22(10):e875-e881. doi: 10.1016/j.hrthm.2025.05.045. Epub 2025 May 23.

DOI:10.1016/j.hrthm.2025.05.045
PMID:40414261
Abstract

BACKGROUND

Catheter-tissue contact is critical in creating durable lesions during pulsed-field ablation (PFA) of atrial fibrillation (AF).

OBJECTIVE

This study aimed to compare the reconnection rate of previously ablated targets using PFA with vs without intracardiac echocardiography (ICE) guidance for confirmation of tissue contact.

METHODS

This multicenter prospective study included consecutive patients with paroxysmal and persistent AF undergoing their first procedure using the PFA system. Patients were classified as the ICE group if ICE was used for the assessment of catheter-tissue contact (n = 310) or the fluoro group if fluoroscopy-guided ablation was used (n = 286). All patients received isolation of pulmonary veins; left atrial posterior wall isolation was performed in most patients at the index procedure. Further ablations were performed only in the presence of spontaneous triggers or documentation that those triggers were responsible for arrhythmia either spontaneously or after isoproterenol challenge.

RESULTS

Baseline characteristics were comparable between the groups. At the end of the follow-up, arrhythmia recurrence was noted in 39 (12.6%) and 64 patients (22.3%) in the ICE and fluoro groups, respectively (P = .002). All 39 patients in the ICE group and 54 patients (84%) in the fluoro group received repeat ablation. At the redo procedure, reconnection of previously ablated structures was detected in 4 of 39 (10.3%) and 32 of 54 patients (59.2%) in the ICE and fluoro groups, respectively (P < .001). "Fluoroscopy-guided" ablation was found to be an independent predictor of reconnection (odds ratio 8.548; 95% confidence interval 3.224-22.667; P < .001) and recurrence (odds ratio 1.221; 95% confidence interval 1.001-1.971; P = .021).

CONCLUSION

ICE-guided PFA with confirmed catheter-tissue contact was associated with a better success rate and a significantly lower reconnection rate in patients with AF.

摘要

相似文献

1
Ensuring catheter-tissue contact with intracardiac echocardiography during pulsed-field ablation improves procedure outcome in patients with atrial fibrillation.
Heart Rhythm. 2025 Oct;22(10):e875-e881. doi: 10.1016/j.hrthm.2025.05.045. Epub 2025 May 23.
2
Repeat procedures after pulsed field ablation for atrial fibrillation: MANIFEST-REDO study.心房颤动脉冲场消融术后重复手术:MANIFEST-REDO研究
Europace. 2025 Aug 4;27(8). doi: 10.1093/europace/euaf012.
3
Near-zero fluoroscopy workflow for pulmonary vein isolation in atrial fibrillation using a variable loop, 3D-integrated circular PFA catheter (Varipulse™): initial single-center experience with the first 35 patients.使用可变环、3D集成环形脉冲电场消融导管(Varipulse™)进行房颤肺静脉隔离的近零透视工作流程:前35例患者的单中心初步经验
J Interv Card Electrophysiol. 2025 Feb 3. doi: 10.1007/s10840-025-01981-5.
4
A tailored substrate-based approach using focal pulsed field catheter ablation in patients with atrial fibrillation and advanced atrial substrate: Procedural data and 6-month success rates.一种针对心房颤动和晚期心房基质患者采用基于定制基质的方法进行局灶性脉冲场导管消融:手术数据和6个月成功率。
Heart Rhythm. 2025 Aug;22(8):1957-1968. doi: 10.1016/j.hrthm.2025.01.015. Epub 2025 Jan 17.
5
Pulsed-field ablation for atrial fibrillation without the use of fluoroscopy.不使用荧光透视法的心房颤动脉冲场消融术。
J Interv Card Electrophysiol. 2025 Jun;68(4):757-765. doi: 10.1007/s10840-024-01904-w. Epub 2024 Aug 23.
6
Posterior wall ablation by pulsed-field ablation: procedural safety, efficacy, and findings on redo procedures.经皮脉冲场消融后壁消融:程序安全性、疗效和再治疗发现。
Europace. 2023 Dec 28;26(1). doi: 10.1093/europace/euae006.
7
Redo ablation procedures to treat recurrent atrial arrhythmias via a pentaspline pulsed field ablation catheter: a prospective, multicenter experience.使用五叶样条脉冲场消融导管进行再次消融手术治疗复发性房性心律失常:一项前瞻性多中心研究。
J Interv Card Electrophysiol. 2025 Sep;68(6):1267-1281. doi: 10.1007/s10840-025-02021-y. Epub 2025 Mar 4.
8
Pulsed Field Ablation of Persistent Atrial Fibrillation With Continuous Electrocardiographic Monitoring Follow-Up: ADVANTAGE AF Phase 2.持续心电图监测随访下的持续性心房颤动脉冲场消融:ADVANTAGE AF 2期研究
Circulation. 2025 Jul 8;152(1):27-40. doi: 10.1161/CIRCULATIONAHA.125.074485. Epub 2025 Apr 24.
9
Esophageal endoscopic findings after pulmonary vein and posterior wall isolation using pulsed field ablation: results from the Eso-PFA study.使用脉冲场消融进行肺静脉和后壁隔离后的食管内镜检查结果:食管-脉冲场消融研究结果
Europace. 2025 Aug 4;27(8). doi: 10.1093/europace/euaf133.
10
Predictors of atrial fibrillation freedom postablation with the pentaspline pulsed field ablation catheter: Subanalysis of the ADVENT Study.使用五样条脉冲场消融导管消融术后房颤缓解的预测因素:ADVENT研究的亚分析
Heart Rhythm. 2025 Mar 6. doi: 10.1016/j.hrthm.2025.03.161.