Brown J J, Peterson T M, Slutsky R A
Invest Radiol. 1985 Aug;20(5):465-71. doi: 10.1097/00004424-198508000-00005.
This study was designed to measure early changes in myocardial perfusion after acute coronary occlusion, and to examine the relationships among blood flow, myocardial edema, and magnetic relaxation times of ex vivo myocardial tissue. In ten dogs, the left anterior descending coronary artery was occluded for 4 hours prior to sacrifice of the animals. Regional myocardial blood flow was measured using radiolabeled microspheres (15 micron), which were injected into the left atrium 5 minutes prior to sacrifice. Multiple subendocardial tissue samples from the left ventricular free wall were obtained for measurement of magnetic relaxation times, percent water content and tissue radioactivity. Mild, moderate, and severe ischemia were defined as reductions in myocardial blood flow to 30% to 50%, 15% to 30%, and less than or equal to 15% of control, respectively. Myocardial water content was increased with mild ischemia (79.6 +/- 0.7%), moderate ischemia (79.9 +/- 0.4%), and severe ischemia (80.3 +/- 0.6%), all P less than .005 vs. control. T1 relaxation times rose with mild (544 +/- 10 msec, P less than .005 vs. control), moderate (543 +/- 11 msec, P less than .005 vs. control), and severe ischemia (574 +/- 10 msec, P less than .001 vs. control). T2 relaxation times behaved in a similar manner, being prolonged in the mildly, moderately, and severely ischemic groups (38.3 +/- 0.3, 38.1 +/- 0.3 and 38.2 +/- 0.3 msec, respectively; all P less than .001 vs. control).(ABSTRACT TRUNCATED AT 250 WORDS)
本研究旨在测量急性冠状动脉闭塞后心肌灌注的早期变化,并研究血流、心肌水肿与离体心肌组织磁弛豫时间之间的关系。在10只犬中,于处死动物前4小时闭塞左前降支冠状动脉。利用放射性微球(15微米)测量局部心肌血流,在处死前5分钟将其注入左心房。从左心室游离壁获取多个心内膜下组织样本,用于测量磁弛豫时间、含水量百分比和组织放射性。轻度、中度和重度缺血分别定义为心肌血流减少至对照值的30%至50%、15%至30%以及小于或等于15%。轻度缺血(79.6±0.7%)、中度缺血(79.9±0.4%)和重度缺血(80.3±0.6%)时心肌含水量均增加,与对照相比,P均小于0.005。T1弛豫时间在轻度缺血(544±10毫秒,与对照相比,P小于0.005)、中度缺血(543±11毫秒,与对照相比,P小于0.005)和重度缺血(574±10毫秒,与对照相比,P小于0.001)时均升高。T2弛豫时间表现类似,在轻度、中度和重度缺血组均延长(分别为38.3±0.3、38.1±0.3和38.2±0.3毫秒;与对照相比,P均小于0.001)。(摘要截选至250词)