Suppr超能文献

黄斑和视神经乳头光学相干断层扫描血管造影中分数维分析的可重复性

Repeatability of Fractal Analysis in OCT Angiography of the Macula and Optic Nerve Head.

作者信息

Gameiro Gustavo Rosa, Jammal Alessandro A, Vilasboas-Campos Verônica, Wang Jianhua, Medeiros Felipe A

机构信息

Bascom Palmer Eye Institute, University of Miami, Miami, Florida.

出版信息

Ophthalmol Sci. 2025 Apr 3;5(5):100784. doi: 10.1016/j.xops.2025.100784. eCollection 2025 Sep-Oct.

Abstract

PURPOSE

To evaluate the repeatability of OCT angiography (OCTA) vessel density measurements using fractal analysis in the macula and optic nerve head (ONH) regions.

DESIGN

A prospective longitudinal observational cohort study.

PARTICIPANTS

One hundred sixteen eyes from 71 primary open-angle glaucoma patients with valid macula OCTA scans and 91 eyes from 59 primary open-angle glaucoma patients with valid ONH OCTA scans, with 53 patients contributing scans for both regions.

METHODS

Participants underwent 5 OCTA imaging sessions at weekly intervals using the Spectralis spectral-domain OCT (Heidelberg Engineering). OCT angiography images were processed for fractal analysis focusing on small vessels (<25 μm in diameter) within slabs of the superficial vascular complex (SVC), deep vascular complex (DVC), full retina, and nerve fiber layer vascular plexus (NFLVP). Vessel density repeatability was assessed using the coefficient of variation (CoV) with bootstrapped 95% confidence intervals. Associations between fractal analysis parameters and peripapillary retinal nerve fiber layer (RNFL) thickness were analyzed.

MAIN OUTCOME MEASURES

Repeatability of OCTA vessel density quantified by fractal analysis and correlation with RNFL thickness.

RESULTS

One thousand three hundred twenty-eight macula OCTA scans from 269 visits and 801 ONH scans from 164 visits were included. Fractal analysis demonstrated high repeatability for vessel density measurements, with CoVs ranging from 0.4% to 0.9% in the macula and 0.7% to 1.8% in the ONH region. Full retina slabs exhibited the best repeatability in both regions, while DVC measurements in the ONH showed the highest variability (CoV = 1.8%). Moderate correlations between fractal parameters and RNFL thickness were observed in the ONH (SVC: rho = 0.65; NFLVP: rho = 0.67;  < 0.001) and macula (SVC: rho = 0.33,  < 0.001).

CONCLUSIONS

High repeatability of OCTA vessel density measurements using fractal analysis was observed in the macula and ONH regions, supporting its potential utility in monitoring vascular changes in glaucoma. Future studies should investigate its diagnostic accuracy and ability to detect disease progression.

FINANCIAL DISCLOSURES

Proprietary or commercial disclosure may be found in the Footnotes and Disclosures at the end of this article.

摘要

目的

评估使用分形分析测量黄斑和视神经乳头(ONH)区域光学相干断层扫描血管造影(OCTA)血管密度的可重复性。

设计

一项前瞻性纵向观察队列研究。

参与者

71例原发性开角型青光眼患者的116只眼有有效的黄斑OCTA扫描结果,59例原发性开角型青光眼患者的91只眼有有效的ONH OCTA扫描结果,其中53例患者两个区域均有扫描结果。

方法

参与者使用Spectralis光谱域OCT(海德堡工程公司),每周进行1次,共进行5次OCTA成像。对OCT血管造影图像进行处理,以进行分形分析,重点关注浅表血管复合体(SVC)、深部血管复合体(DVC)、全视网膜和神经纤维层血管丛(NFLVP)板层内直径小于25μm的小血管。使用变异系数(CoV)和自抽样95%置信区间评估血管密度的可重复性。分析分形分析参数与视乳头周围视网膜神经纤维层(RNFL)厚度之间的相关性。

主要观察指标

通过分形分析量化的OCTA血管密度的可重复性以及与RNFL厚度的相关性。

结果

纳入了269次就诊的1328次黄斑OCTA扫描和164次就诊的801次ONH扫描。分形分析显示血管密度测量具有高可重复性,黄斑区域的CoV范围为0.4%至0.9%,ONH区域为0.7%至1.8%。全视网膜板层在两个区域均表现出最佳的可重复性,而ONH区域的DVC测量显示出最高的变异性(CoV = 1.8%)。在ONH(SVC:rho = 0.65;NFLVP:rho = 0.67;P < 0.001)和黄斑(SVC:rho = 0.33,P < 0.001)中观察到分形参数与RNFL厚度之间存在中度相关性。

结论

在黄斑和ONH区域观察到使用分形分析测量OCTA血管密度具有高可重复性,支持其在监测青光眼血管变化方面的潜在效用。未来的研究应调查其诊断准确性和检测疾病进展的能力。

财务披露

在本文末尾的脚注和披露中可能会找到专有或商业披露信息。

https://cdn.ncbi.nlm.nih.gov/pmc/blobs/7c2d/12127646/673300c51052/gr1.jpg

文献AI研究员

20分钟写一篇综述,助力文献阅读效率提升50倍。

立即体验

用中文搜PubMed

大模型驱动的PubMed中文搜索引擎

马上搜索

文档翻译

学术文献翻译模型,支持多种主流文档格式。

立即体验