The long-lever hip adduction squeeze test is a feasible and quick way to measure maximal hip adduction strength, which is associated with groin injury risk. Excellent week-to-week reliability has been established in senior elite football. Youth elite players often engage in physical activities outside of the football academy, which may affect reliability. This study aimed to investigate the week-to-week reliability of the long-lever hip adduction squeeze strength in a youth elite academy football setting using a novel groin strength testing device.
Seventy-nine youth elite male football players from the U13 to U19 teams of a youth elite football academy were included. During four consecutive weeks, players were tested weekly at the same day each week (match day +2), using a long-lever hip adduction squeeze device with maximal strength recorded. Players who reported groin pain of >2 out of 10 during testing were excluded.
No systematic bias was observed between the different testing weeks (p>0.5). Good and consistent relative week-to-week reliability was observed (ICC: 0.916-0.933). Absolute reliability (SEM %) ranged from 7.6-8.6%, with MDCind % and MDCgroup % ranging from 21.2-24 % and 3.3-5.8 %, respectively.
Week-to-week measures of long-lever hip adduction strength showed good relative and absolute reliability, and thus can be used in the academy setting to reliably screen for groin injury risk.
长杠杆髋关节内收挤压试验是一种可行且快速的测量最大髋关节内收力量的方法,该力量与腹股沟损伤风险相关。在高级精英足球运动员中已确立了良好的周周可靠性。青年精英球员经常在足球学院之外参加体育活动,这可能会影响可靠性。本研究旨在使用一种新型腹股沟力量测试装置,调查青年精英足球学院环境中长杠杆髋关节内收挤压力量的周周可靠性。
纳入了一所青年精英足球学院U13至U19球队的79名青年精英男性足球运动员。在连续四周内,球员们每周在同一天(比赛日+2)进行测试,使用长杠杆髋关节内收挤压装置记录最大力量。测试期间报告腹股沟疼痛程度大于10分制中的2分的球员被排除。
在不同测试周之间未观察到系统偏差(p>0.5)。观察到良好且一致的周周相对可靠性(ICC:0.916 - 0.933)。绝对可靠性(SEM%)范围为7.6 - 8.6%,个体最小可检测变化百分比(MDCind%)和群体最小可检测变化百分比(MDCgroup%)分别为21.2 - 24%和3.3 - 5.8%。
长杠杆髋关节内收力量的周周测量显示出良好的相对和绝对可靠性,因此可用于学院环境中可靠地筛查腹股沟损伤风险。