Abstract

PURPOSE

This study aimed to compare the adhesion of Asian dust to four types of reusable silicone hydrogel soft contact lenses (SiHySCLs), including lehfilcon A, which was recently introduced in the market.

METHODS

Four types of SiHySCLs available in Japan (senofilcon A, samfilcon A, comfilcon A, lehfilcon A) were used (10 lenses per group). A 0.2 mL drop of phosphate-buffered saline (PBS) containing 0.01 mg/mL of Asian dust was randomly applied on the surface of the soft contact lens (SCL) using the Latin squares method. This was followed by 1 min of gentle agitation and 1 min of vibrational stirring after 1 h of static incubation. The lens was subsequently washed three times with PBS. The area of the Asian dust that had adhered after washing was quantified.

RESULTS

The proportion of residual particles adhering to the SiHySCL surface was as follows: senofilcon A (6.6 ± 1.3%), samfilcon A (0.6 ± 0.2%), comfilcon A (0.8 ± 0.4%), lehfilcon A (0.1 ± 0.1%). Compared to the other lenses, lehfilcon A exhibited significantly lower adhesion to Asian dust (all p < 0.01).

CONCLUSION

Lehfilcon A demonstrated minimal adhesion of Asian dust components among the assessed reusable SiHySCLs, suggesting that it is a favorable option during periods of Asian dust exposure.

摘要

目的

本研究旨在比较亚洲沙尘在四种类型的可重复使用的硅水凝胶软性隐形眼镜(SiHySCLs)上的附着情况,其中包括最近上市的乐菲康A。

方法

使用在日本可得的四种类型的SiHySCLs(senofilcon A、samfilcon A、comfilcon A、乐菲康A)(每组10片镜片)。采用拉丁方方法,将0.2 mL含有0.01 mg/mL亚洲沙尘的磷酸盐缓冲盐水(PBS)随机滴在软性隐形眼镜(SCL)表面。在静态孵育1小时后,进行1分钟的轻柔搅拌,然后进行1分钟的振动搅拌。随后用PBS将镜片冲洗三次。对冲洗后附着的亚洲沙尘面积进行定量。

结果

附着在SiHySCL表面的残留颗粒比例如下:senofilcon A(6.6±1.3%)、samfilcon A(0.6±0.2%)、comfilcon A(0.8±0.4%)、乐菲康A(0.1±0.1%)。与其他镜片相比,乐菲康A对亚洲沙尘的附着显著更低(所有p<0.01)。

结论

在评估的可重复使用的SiHySCLs中,乐菲康A对亚洲沙尘成分的附着最小,这表明在亚洲沙尘暴露期间它是一个有利的选择。