Feng C S, Kirkley K C, Eicher C A, de Jongh D S
Transfusion. 1985 Sep-Oct;25(5):433-4. doi: 10.1046/j.1537-2995.1985.25586020117.x.
The Lui elution and the heat elution techniques are the most simple techniques available for eluting antibodies from red cells. Both are very effective for eluting ABO antibodies. We compared the two techniques and found the Lui technique superior in that it more efficiently eluted ABO antibodies, required less hands-on time, and allowed more flexibility in the procedure. We therefore recommend the Lui elution technique as the method of choice for eluting ABO antibodies, especially for the evaluation of hemolytic disease of the newborn.
吕伊洗脱法和热洗脱法是从红细胞中洗脱抗体最简便的技术。两者在洗脱ABO抗体方面都非常有效。我们比较了这两种技术,发现吕伊技术更具优势,因为它能更有效地洗脱ABO抗体,所需的实际操作时间更少,并且在操作过程中具有更大的灵活性。因此,我们推荐吕伊洗脱法作为洗脱ABO抗体的首选方法,尤其是用于新生儿溶血病的评估。