A simple apparatus using the infrared ray, which can divide spontaneous motor activity (SMA) of mice into two behavioral components, a vertical movement (VM) and a horizontal movement (HM) was designed. VM and HM were evaluated by counting the number of times that infrared rays were blocked by the mouse in the activity cage [300(H) X 260(D) X 130(W) mm] with 9 infrared photo-couplers for measuring VM and one infrared photo-coupler for measuring HM. When methamphetamine (MAM) was subcutaneously administered to mice pretreated with saline (0.1 ml/10 g, sc) for 3 days, VM and HM were as follows: 1) At 0.1 mg/kg of MAM, the same level of activity was observed as with saline. 2) At 1.0 mg/kg of MAM, increased activity was noted. 3) At 10 mg/kg of MAM, a marked increase was noted, showing more enhancement of HM than VM, which had developed into a stereotyped behavior. In summary, this new apparatus was found capable of dividing the SMA of mice into the two behavioral patterns of VM and HM, and providing their measurements.

摘要

设计了一种使用红外线的简单装置,该装置可将小鼠的自发运动活动(SMA)分为两个行为成分,即垂直运动(VM)和水平运动(HM)。通过计算活动笼[300(长)X 260(深)X 130(宽)mm]中红外线被小鼠阻挡的次数来评估VM和HM,其中有9个用于测量VM的红外光电耦合器和1个用于测量HM的红外光电耦合器。当对用生理盐水(0.1 ml/10 g,皮下注射)预处理3天的小鼠皮下注射甲基苯丙胺(MAM)时,VM和HM的情况如下:1)在MAM剂量为0.1 mg/kg时,观察到的活动水平与生理盐水组相同。2)在MAM剂量为1.0 mg/kg时,活动增加。3)在MAM剂量为10 mg/kg时,活动显著增加,显示HM的增强比VM更明显,且VM已发展为刻板行为。总之,发现这种新装置能够将小鼠的SMA分为VM和HM两种行为模式,并对其进行测量。

文献AI研究员

20分钟写一篇综述,助力文献阅读效率提升50倍。

立即体验

用中文搜PubMed

大模型驱动的PubMed中文搜索引擎

马上搜索

文档翻译

学术文献翻译模型,支持多种主流文档格式。

立即体验