Microcannulas used during vitreous surgery protect the entry site, avoid vitreous base damage, and allow easy exchange of 20- and 19-gauge (0.9- and 1-mm) instruments. The use of three cannulas of equal size permits interchangeability of all instruments. A locking mechanism allows attachment and exchange of various infusion lines (balanced salt solution, gas, and oil). Temporary plugging of the cannula is possible. Selection of 1 mm as a standard diameter for all cannulas make multiple-function instruments feasible.
玻璃体手术中使用的微型套管可保护进入部位,避免玻璃体基底部受损,并便于20号和19号(0.9毫米和1毫米)器械的轻松更换。使用三个尺寸相同的套管可使所有器械具有互换性。锁定机制允许连接和更换各种输液管(平衡盐溶液、气体和油)。套管可以临时堵塞。选择1毫米作为所有套管的标准直径使多功能器械成为可能。