Suppr超能文献

从坐姿到站姿是一种评估成年儿童癌症幸存者力量、爆发力和速度训练的新的可靠方法。

Sit to stand is a new reliable method for assessing strength, power, and velocity exercise in adult pediatric cancer survivors.

作者信息

Rodríguez-Perea Ángela, Jerez-Mayorga Daniel, Ubago-Guisado Esther, Marmol-Perez Andres, Jiménez-Lupión Daniel, Rodríguez-Solana Andrea, Rios Luis Javier Chirosa, Llorente-Cantarero Francisco J, Herrada-Robles María, Gracia-Marco Luis

机构信息

Faculty of Physical Activity and Sports Sciences, Department of Physical and Sport Education, Universidad de León, León, Spain.

Department of Physical Education and Sport, Faculty of Sports Sciences, University of Granada, Granada, Spain.

出版信息

J Cancer Res Clin Oncol. 2025 Jun 14;151(6):189. doi: 10.1007/s00432-025-06225-7.

Abstract

PURPOSE

We aimed to analyze the intra-set reliability of 5 sit-to-stand (5-STS) exercises with a functional electromechanical dynamometer (FEMD) and to determine and compare the load-velocity (L-V) profile in the STS exercise in adult pediatric cancer survivors by sex, age, body mass index, and type and treatment of cancer.

METHOD

A total of 47 participants performed the 5-STS test with 5% and 20% body weight (BW) to assess intrasession reliability and analyze differences in L-V profiles by sex, age, BMI, and type and treatment of cancer.

RESULTS

Very high and extremely high relative reliability was found for both the 5% STS (ICC = 0.80-0.94) and the 20% STS (ICC = 0.87-0.95) relate to average and peak force, power, and velocity. Regarding L-V profiles, significant differences were only found in relation to sex for the velocity-axis intercept and area under the line (p < 0.05).

CONCLUSION

The 5-STS test with a load of 5% and 20% of BW using a FEMD is a reliable method for assessing strength, power, and velocity exercise in adult pediatric cancer survivors. There was a relation to sex for the variables of L-V profile.

IMPLICATIONS FOR CANCER SURVIVORS

Reliable assessments of muscular strength, like the 5-STS test using FEMD, offer a safer, less demanding alternative to maximal strength tests (e.g., 1RM), enabling precise intensity control and better-tailored rehabilitation programs.

摘要

目的

我们旨在分析使用功能性电动测力计(FEMD)进行5次坐立试验(5-STS)的组内可靠性,并根据性别、年龄、体重指数以及癌症类型和治疗情况,确定并比较成年儿童癌症幸存者在坐立试验中的负荷-速度(L-V)曲线。

方法

共有47名参与者进行了5-STS测试,负荷分别为体重的5%和20%,以评估组内可靠性,并分析L-V曲线在性别、年龄、体重指数以及癌症类型和治疗方面的差异。

结果

对于5% STS(组内相关系数ICC = 0.80 - 0.94)和20% STS(ICC = 0.87 - 0.95),在平均和峰值力、功率及速度方面均发现了非常高和极高的相对可靠性。关于L-V曲线,仅在速度轴截距和曲线下面积方面发现了与性别相关的显著差异(p < 0.05)。

结论

使用FEMD进行负荷为体重5%和20%的5-STS测试,是评估成年儿童癌症幸存者力量、功率和速度锻炼的可靠方法。L-V曲线变量与性别有关。

对癌症幸存者的意义

像使用FEMD进行5-STS测试这样对肌肉力量的可靠评估,为最大力量测试(如1RM)提供了一种更安全、要求更低的替代方法,能够实现精确的强度控制和更个性化的康复计划。

https://cdn.ncbi.nlm.nih.gov/pmc/blobs/270f/12166015/fed8dd948556/432_2025_6225_Fig1_HTML.jpg

文献检索

告别复杂PubMed语法,用中文像聊天一样搜索,搜遍4000万医学文献。AI智能推荐,让科研检索更轻松。

立即免费搜索

文件翻译

保留排版,准确专业,支持PDF/Word/PPT等文件格式,支持 12+语言互译。

免费翻译文档

深度研究

AI帮你快速写综述,25分钟生成高质量综述,智能提取关键信息,辅助科研写作。

立即免费体验