The patient was a 21-year-old male who underwent the Jatene procedure at 5 months of age for posterior transposition of the great arteries (double-outlet right ventricular type). At 4 years of age, the patient underwent mechanical aortic valve replacement with aortic root augmentation using an expanded polytetrafluoroethylene patch for severe neo-aortic regurgitation. Mechanical valve failure occurred due to pannus formation. We performed the Bentall procedure on the aortic root, which involved the pulmonary artery and a severely calcified expanded polytetrafluoroethylene patch. A composite graft was safely positioned on the anatomic right ventricular outflow tract aortic root under four-dimensional imaging guidance.
该患者为21岁男性,5个月大时因大动脉后位转位(双出口右心室型)接受了贾滕手术。4岁时,因严重的新主动脉瓣反流,患者接受了机械主动脉瓣置换术,并使用膨体聚四氟乙烯补片进行主动脉根部扩大术。因血管翳形成导致机械瓣膜功能障碍。我们对主动脉根部进行了本特利手术,该手术涉及肺动脉和严重钙化的膨体聚四氟乙烯补片。在四维成像引导下,将复合移植物安全地置于解剖学右心室流出道主动脉根部。