Suppr超能文献

用于循环死亡后猪肝脏边缘移植物捐献的与机器灌注相连的血液吸附柱。

Haemoadsorption cartridge connected to the machine perfusion for donation after circulatory death porcine liver marginal grafts.

作者信息

Scalera Irene, Franzin Rossana, Stasi Alessandra, Castellaneta Antonino, Fischetti Enrico, Morelli Giulia, Raele Margherita, Panetta Emilio, Kurevija Andjela, Pulga William, Atti Mauro, Gesualdo Loreto

机构信息

Hepatobiliary and Liver Transplant Unit, University Hospital Policlinic of Bari, Bari 70124, Puglia, Italy.

Division of Nephrology, Department of Dialysis and Transplant, University Hospital Policlinic of Bari, Bari 70124, Puglia, Italy.

出版信息

World J Transplant. 2025 Jun 18;15(2):99287. doi: 10.5500/wjt.v15.i2.99287.

Abstract

BACKGROUND

Marginal donation after circulatory death (DCD) liver grafts are carefully used to combat the constant shortage of donors. Clinically, the worst outcomes are mainly related to severe ischemia-reperfusion-injury and the dangerous effect of various inflammatory cytokines (CK). The machine perfusion (MP) is a promising device to rescue these grafts.

AIM

To analyze the role of MP connected to a sorbent cartridge (PerSorb) and used for very damaged DCD pig livers.

METHODS

Seven grafts were procured from pigs from a slaughterhouse. Grafts were made very marginal with at least 60 minutes of donor warm ischemia time and 24 hours of static-cold ischemia time: (1) 3 grafts were perfused in hypothermic MP with PerSorb (Sorb); (2) 2 other grafts in hypothermic MP (HMP) without the cartridge (NoSorb); and (3) The other 2 livers stored in the ice box (NoTreat). The CK were measured at HMP start (T0) and at the end (Tend). Biopsies were taken at T0 and Tend.

RESULTS

All 5 grafts treated with HMP had a negative lactate trend after 3 hours of treatment (8.83 at T0 6.4 at Tend of Sorb; 15 at T0 5.45 at Tend for NoSorb, value > 0.05). At Tend, both Sorb and NoSorb groups had better hemodynamic parameters, comparable between the two groups. Enzyme-linked immunosorbent assay analysis showed a reduction of monocyte chemotactic protein-1, tumor necrosis factor-alpha and interleukin-1β for NoSorb group at Tend and a complete downregulation to physiological levels of the same CK in Sorb livers after 3 hours of treatment. Biopsies showed a reduction of the perisinusoidal edema for the Sorb grafts compared with the NoSorb livers.

CONCLUSION

These data suggest a potential protective role of treatment of grafts with MP and sorbent cartridge in reducing the inflammatory response after a severe ischemic injury.

摘要

背景

心脏死亡后捐献(DCD)边缘性肝移植被谨慎用于应对供体持续短缺的问题。临床上,最糟糕的结果主要与严重的缺血再灌注损伤以及各种炎性细胞因子(CK)的危险作用有关。机器灌注(MP)是拯救这些移植物的一种有前景的设备。

目的

分析连接吸附柱(PerSorb)的机器灌注在挽救严重受损的DCD猪肝脏中的作用。

方法

从屠宰场的猪身上获取7个移植物。通过至少60分钟的供体热缺血时间和24小时的静态冷缺血时间使移植物边缘性增加:(1)3个移植物在低温机器灌注下用PerSorb(Sorb)进行灌注;(2)另外2个移植物在低温机器灌注(HMP)下不使用吸附柱(NoSorb);(3)另外2个肝脏保存在冰盒中(未处理,NoTreat)。在机器灌注开始时(T0)和结束时(Tend)测量细胞因子。在T0和Tend时进行活检。

结果

所有5个接受低温机器灌注治疗的移植物在治疗3小时后乳酸水平呈下降趋势(Sorb组T0时为8.83,Tend时为6.4;NoSorb组T0时为15,Tend时为5.45;P值>0.05)。在Tend时,Sorb组和NoSorb组的血流动力学参数均较好,两组之间相当。酶联免疫吸附测定分析显示,NoSorb组在Tend时单核细胞趋化蛋白-1、肿瘤坏死因子-α和白细胞介素-1β减少,而Sorb组在治疗3小时后这些细胞因子完全下调至生理水平。活检显示,与NoSorb组肝脏相比,Sorb组移植物的肝窦周水肿减轻。

结论

这些数据表明,用机器灌注和吸附柱治疗移植物在减轻严重缺血损伤后的炎症反应方面具有潜在的保护作用。

https://cdn.ncbi.nlm.nih.gov/pmc/blobs/ffb4/11886301/cf60c89266c4/99287-g001.jpg

文献AI研究员

20分钟写一篇综述,助力文献阅读效率提升50倍。

立即体验