Correlation of Biometric Parameters With Endothelial Distance in EVO ICL Phakic Lens Implantation.

作者信息

J Beltrán-Murcia, L Álvarez-Rementería Capelo, V Blázquez-Sánchez

机构信息

Department of Optometry and Vision, Faculty of Optics and Optometry, Universidad Complutense de Madrid, Madrid, Spain.

Clínica Rementería, Madrid, Spain.

出版信息

J Ophthalmol. 2025 Jun 12;2025:6959314. doi: 10.1155/joph/6959314. eCollection 2025.

Abstract

The correlations between different parameters and the positioning of the EVO ICL were analyzed. Significant correlations were observed, highlighting the relationship between the endothelium and the anterior surface of the phakic ICL lens. However, it is important to note that GAP is only a postoperative measure and cannot be used to directly define the correct positioning of the EVO ICL. The study emphasizes these correlations, without drawing conclusions regarding the causal relationships between the parameters. In this retrospective, observational, transversal analytic study, patients who underwent refractive surgery with implanted EVO ICL pIOL were analyzed. The distance between corneal endothelium and anterior surface of ICL (GAP) was measured postoperatively at 1 week and 1 month using ANTERION AS-OCT. 35 eyes of 35 patients were analyzed. The mean GAP values at 1 week and 1 month were 2.5 ± 0.2 mm and 2.6 ± 0.2 mm, respectively ( = 0.002), increasing its value. The GAP value correlated positively with preoperative anterior chamber volume, white-to-white, lens vault, spur-spur distance, anterior chamber angle distance, and anterior chamber angles values. The correlations between GAP and pre- and postoperative variables highlight its relationship with anterior segment anatomy after EVO ICL implantation. However, as a postoperative measurement, GAP does not determine the correct positioning of the lens.

摘要

分析了不同参数与EVO ICL定位之间的相关性。观察到显著的相关性,突出了内皮与有晶状体ICL镜片前表面之间的关系。然而,需要注意的是,GAP只是一种术后测量指标,不能用于直接确定EVO ICL的正确定位。该研究强调了这些相关性,但未就参数之间的因果关系得出结论。在这项回顾性、观察性、横向分析研究中,对接受植入EVO ICL pIOL屈光手术的患者进行了分析。术后1周和1个月使用ANTERION AS-OCT测量角膜内皮与ICL前表面之间的距离(GAP)。分析了35例患者的35只眼。1周和1个月时的平均GAP值分别为2.5±0.2mm和2.6±0.2mm(P = 0.002),其值增加。GAP值与术前前房容积、白对白、晶状体拱高、嵴-嵴距离、前房角距离和前房角值呈正相关。GAP与术前和术后变量之间的相关性突出了其与EVO ICL植入后眼前节解剖结构的关系。然而,作为一种术后测量指标,GAP并不能确定晶状体的正确定位。

https://cdn.ncbi.nlm.nih.gov/pmc/blobs/d3a2/12178738/c6a650b31f28/JOPH2025-6959314.001.jpg

文献检索

告别复杂PubMed语法,用中文像聊天一样搜索,搜遍4000万医学文献。AI智能推荐,让科研检索更轻松。

立即免费搜索

文件翻译

保留排版,准确专业,支持PDF/Word/PPT等文件格式,支持 12+语言互译。

免费翻译文档

深度研究

AI帮你快速写综述,25分钟生成高质量综述,智能提取关键信息,辅助科研写作。

立即免费体验