Abstract

PURPOSE

To evaluate the repeatability of the binocular Esterman visual field (bEVF) test and develop a corresponding reliability criterion based on repeatability-associated factors.

STUDY DESIGN

Prospective cross-sectional study.

METHODS

Ninety-five glaucoma patients underwent two bEVF tests on the same day using a Humphrey field analyzer. The repeatability of the bEVF was assessed by the agreement rate for seen and unseen points over all test points between the first and second tests. Factors associated with the repeatability were analyzed with multivariate linear regression analysis. Receiver operating characteristic (ROC) curve analysis was performed for those associated factors to identify the reliability criterion.

RESULTS

The mean agreement rate was 88.9% (95% confidence interval [CI]: 73.9%, 99.2%). A total of 44 patients (46.3%), 75 patients (78.9%), and 88 patients (92.6%) had agreement rates of more than 90%, 85%, and 80%, respectively. The false positive (FP) response rate of the bEVF test was negatively associated with the agreement rate (p<0.01). The best cutoff value according to the maximum Youden index for the FP response rate of the bEVF test was >7.1% (sensitivity = 71.0% and specificity = 88.0%), while the cutoff value based on a fixed 95% specificity was >12.1% (sensitivity = 28.6%).

CONCLUSION

An approximately 90% agreement rate existed for the bEVF test when applied to glaucoma patients. The FP response rate was associated with the repeatability of the bEVF test, and 8% or at least 13% may serve as a useful reference to ensure an agreement rate of 80% or higher.

摘要

目的

评估双眼Esterman视野(bEVF)测试的可重复性,并基于与可重复性相关的因素制定相应的可靠性标准。

研究设计

前瞻性横断面研究。

方法

95例青光眼患者在同一天使用Humphrey视野分析仪进行两次bEVF测试。通过第一次和第二次测试中所有测试点上可见和不可见点的一致率来评估bEVF的可重复性。采用多元线性回归分析与可重复性相关的因素。对这些相关因素进行受试者操作特征(ROC)曲线分析以确定可靠性标准。

结果

平均一致率为88.9%(95%置信区间[CI]:73.9%,99.2%)。分别有44例患者(46.3%)、75例患者(78.9%)和88例患者(92.6%)的一致率超过90%、85%和80%。bEVF测试的假阳性(FP)反应率与一致率呈负相关(p<0.01)。根据bEVF测试FP反应率的最大约登指数,最佳截断值>7.1%(敏感性=71.0%,特异性=88.0%),而基于固定95%特异性的截断值>12.1%(敏感性=28.6%)。

结论

当应用于青光眼患者时,bEVF测试的一致率约为90%。FP反应率与bEVF测试的可重复性相关,8%或至少13%可作为确保80%或更高一致率的有用参考。