Suppr超能文献

X线片上股骨近端骨骺方向参数的观察者内和观察者间可靠性分析比较

Comparison of intra-and interobserver reliability analysis of orientation proximal femur physis parameters on radiographs.

作者信息

Garg Varun, Agarwal Anil, Sachdeva Kishmita, Ankitha K S

机构信息

Department of Pediatric Orthopedics, Chacha Nehru Bal Chikitsalaya, New Delhi, India.

出版信息

J Clin Orthop Trauma. 2025 Jun 7;68:103093. doi: 10.1016/j.jcot.2025.103093. eCollection 2025 Sep.

Abstract

BACKGROUND

The orientation of proximal femur physis is important as it can cause 3-dimensional deformity of the proximal femur. Recently, authors have described various parameters to describe the orientation of proximal femur physis. Therefore, we aim to compare the intra and interobserver reliability of these parameters in this study.

METHODS

Radiographs of the bilateral hip with the pelvis of children between 1 and 10 years of age were retrieved from the hospital archives to measure the Physeal orientation angle (PO), Physeal tilt angle (PTA), Head shaft angle (HSA), and Alsberg angle (AA). Intra- and inter-observer reliability was tested using Pearson's correlation coefficient and Cronbach's alpha respectively by three independent observers at two separate times, two weeks apart.

RESULTS

The total analysis included 179 radiographs, including 378 hips. PO, PTA, HSA, and AA had values ranging from 9.57 -14.04, 19.62°-25.04, 58.75°-65.82, and 24.47 -31.79, respectively, for the six data sets (three observers at two different times).The intra-observer reliability of PO, PTA, HSA, and AA ranged from 0.59- 0.72, 0.9-0.95, 0.91-0.95 and 0.86-0.95 respectively. PO, PTA, HSA, and AA had inter-observer reliability values between 0.79 -0.82, 0.88-0.92, 0.85-0.88, and 0.89-0.92, respectively.

CONCLUSION

The study found that PTA, AA, and HSA have shown good reliability, but they may not accurately represent the true orientation of the capital femoral physis with respect to the femoral neck. For routine follow-up, PO may be a suitable alternative. However, it is not as reliable as other parameters.

摘要

背景

股骨近端骨骺的方向很重要,因为它可能导致股骨近端的三维畸形。最近,有作者描述了各种参数来描述股骨近端骨骺的方向。因此,我们旨在比较本研究中这些参数在观察者内和观察者间的可靠性。

方法

从医院档案中检索1至10岁儿童双侧髋关节及骨盆的X线片,以测量骨骺方向角(PO)、骨骺倾斜角(PTA)、头干角(HSA)和阿斯伯格角(AA)。由三名独立观察者在相隔两周的两个不同时间分别使用皮尔逊相关系数和克朗巴赫α系数测试观察者内和观察者间的可靠性。

结果

总共分析了179张X线片,包括378个髋关节。六个数据集(三名观察者在两个不同时间)的PO、PTA、HSA和AA值分别为9.57 - 14.04、19.62° - 25.04、58.75° - 65.82和24.47 - 31.79。PO、PTA、HSA和AA的观察者内可靠性分别为0.59 - 0.72、0.9 - 0.95、0.91 - 0.95和0.86 - 0.95。PO、PTA、HSA和AA的观察者间可靠性值分别在0.79 - 0.82、0.88 - 0.92、0.85 - 0.88和0.89 - 0.92之间。

结论

该研究发现,PTA、AA和HSA显示出良好的可靠性,但它们可能无法准确代表股骨头骨骺相对于股骨颈的真实方向。对于常规随访,PO可能是一个合适的替代指标。然而,它不如其他参数可靠。

文献检索

告别复杂PubMed语法,用中文像聊天一样搜索,搜遍4000万医学文献。AI智能推荐,让科研检索更轻松。

立即免费搜索

文件翻译

保留排版,准确专业,支持PDF/Word/PPT等文件格式,支持 12+语言互译。

免费翻译文档

深度研究

AI帮你快速写综述,25分钟生成高质量综述,智能提取关键信息,辅助科研写作。

立即免费体验