: Descemet stripping automated endothelial keratoplasty (DSAEK) is a widely used surgical technique for treating corneal endothelial dysfunctions such as Fuchs endothelial corneal dystrophy (FECD) and pseudophakic bullous keratopathy (PBK). This study aimed to investigate the association between postoperative visual acuity and various corneal morphological and optical parameters, including corneal densitometry (CD) and higher-order aberrations (HOAs), measured using the Pentacam (OCULUS Optikgeräte GmbH, Wetzlar, Germany), as well as graft thickness, which was assessed by anterior segment optic coherence tomography (AS-OCT), (Optovue Inc., Fremont, CA, USA), and corneal thickness, assessed by both AS-OCT and Pentacam. : This prospective, observational cohort study included 17 eyes from 13 patients who underwent DSAEK. Data on preoperative visual acuity were collected, while postoperative parameters were assessed during follow-up visits. Corneal measurements included the total corneal and corneal graft thickness, corneal densitometry in 20 defined subregions, and corneal higher-order aberrations. Associations between these parameters and postoperative visual acuity were evaluated using nonparametric statistical tests. : The postoperative visual acuity improved significantly ( < 0.001). Strong correlations were found between poorer visual acuity and higher CD values. The strongest correlations with visual acuity were found for CD 2-6 mm total (Rho = 0.795; < 0.001), CD central 2-6 mm (Rho = 0.791; < 0.001), and CD central 0-2 mm (Rho = 0.730; < 0.001). Significant associations were also observed with anterior and posterior HOAs (Rho = 0.624, = 0.01; and Rho = 0.556, = 0.02, respectively). No correlation was found between visual outcomes and graft thickness measured by AS-OCT (Rho = 0.051; = 0.85), nor with total corneal thickness measured by AS-OCT (Rho = -0.227; = 0.38) or Pentacam (Rho = -0.369; = 0.14). : This study demonstrates that CD and HOAs are more strongly associated with postoperative visual acuity after DSAEK than traditionally monitored parameters such as graft or corneal thickness. The results highlight the value of detailed corneal imaging and support the use of advanced optical diagnostics in postoperative evaluation.
角膜后弹力层剥除自动内皮角膜移植术(DSAEK)是一种广泛应用于治疗角膜内皮功能障碍的手术技术,如Fuchs内皮角膜营养不良(FECD)和人工晶状体眼大泡性角膜病变(PBK)。本研究旨在探讨术后视力与各种角膜形态学和光学参数之间的关联,这些参数包括使用Pentacam(德国韦茨拉尔OCULUS Optikgeräte GmbH公司)测量的角膜密度计(CD)和高阶像差(HOA),以及通过眼前节光学相干断层扫描(AS-OCT)评估的移植片厚度(美国加利福尼亚州弗里蒙特Optovue公司),还有通过AS-OCT和Pentacam评估的角膜厚度。
这项前瞻性观察队列研究纳入了13例接受DSAEK手术的患者的17只眼睛。收集了术前视力数据,同时在随访期间评估术后参数。角膜测量包括角膜总厚度和角膜移植片厚度、20个定义子区域的角膜密度计测量值以及角膜高阶像差。使用非参数统计检验评估这些参数与术后视力之间的关联。
术后视力显著提高(<0.001)。发现视力较差与较高的CD值之间存在强相关性。与视力相关性最强的是总CD 2 - 6 mm(Rho = 0.795;<0.001)、中央CD 2 - 6 mm(Rho = 0.791;<0.001)和中央CD 0 - 2 mm(Rho = 0.730;<0.001)。还观察到与前、后高阶像差有显著关联(分别为Rho = 0.624, = 0.01;和Rho = 0.556, = 0.02)。未发现视力结果与AS-OCT测量的移植片厚度之间存在相关性(Rho = 0.051; = 0.85),也未发现与AS-OCT测量的角膜总厚度(Rho = -0.227; = 0.38)或Pentacam测量的角膜总厚度(Rho = -0.369; = 0.14)存在相关性。
本研究表明,与传统监测参数如移植片或角膜厚度相比,CD和HOA与DSAEK术后视力的相关性更强。结果突出了详细角膜成像的价值,并支持在术后评估中使用先进的光学诊断方法。