This study aimed to evaluate the influence of a screw coating on the screw preload and removal torque value (RTV) with and without the application of a cyclic load (CL) to make screws with greater untightening resistance to prevent screw loosening. : Ninety complexes composed of implants, abutments, and prosthetic screws were examined and tested under CL oral conditions ( 45) and non-CL conditions (nCL, 45). Each group was divided into three subgroups ( = 15): a control group (CG) without a screw coating, a GapSeal-coated screw group (GG), and a polytetrafluoroethylene (PTFE) tape-wrapped screw group (PG). All screws were tightened at 30 Ncm, and the preload was recorded. In the nCL group, the screws were untightened to record the RTV. In the CL group, the screws were tightened, subjected to a CL in distillated water at a temperature of 37 °C, and then untightened to record the RTV. Micro-Ct analysis was conducted on two samples from each group before CL. SEM analyses of two samples per subgroup before and after CL were also performed. : The preload in the PG was significantly lower under nCL (29.92 Ncm) compared with CG (30.95 Ncm) and GG (31.19 Ncm) and also under a CL (PG: 30.92 Ncm) compared with CG (31.72 Ncm) and GG (31.42 Ncm). The RTVs of the PG were significantly lower under nCL (15.30 Ncm) compared with CG (27.98 Ncm) and GG (28.46 Ncm). Under CL, the RTVs of the PG were significantly higher (31.50 Ncm) compared with CG (26.00 Ncm) and GG (27.44 Ncm). : Wrapping the screw with PTFE tape significantly reduced the preload but resulted in a significantly greater RTV under CL conditions in the simulated oral environment, suggesting that this could be a solution to decrease the risk of screw loosening.
本研究旨在评估螺钉涂层对螺钉预紧力和去除扭矩值(RTV)的影响,在施加和不施加循环载荷(CL)的情况下,使螺钉具有更大的抗松动能力以防止螺钉松动。对由种植体、基台和修复螺钉组成的90个复合体在CL口腔条件(45)和非CL条件(nCL,45)下进行检查和测试。每组分为三个亚组(=15):无螺钉涂层的对照组(CG)、GapSeal涂层螺钉组(GG)和聚四氟乙烯(PTFE)带缠绕螺钉组(PG)。所有螺钉均以30 Ncm拧紧,并记录预紧力。在nCL组中,拧松螺钉以记录RTV。在CL组中,拧紧螺钉,在37℃蒸馏水中施加CL,然后拧松以记录RTV。在CL之前对每组的两个样本进行显微CT分析。还对每个亚组在CL之前和之后的两个样本进行扫描电子显微镜(SEM)分析。与CG(30.95 Ncm)和GG(31.19 Ncm)相比,PG在nCL下的预紧力(29.92 Ncm)显著较低,与CG(31.72 Ncm)和GG(31.42 Ncm)相比,在CL下(PG:30.92 Ncm)也显著较低。与CG(27.98 Ncm)和GG(28.46 Ncm)相比,PG在nCL下的RTV(15.30 Ncm)显著较低。在CL下,PG的RTV(31.50 Ncm)与CG(26.00 Ncm)和GG(27.44 Ncm)相比显著更高。用PTFE带缠绕螺钉显著降低了预紧力,但在模拟口腔环境中的CL条件下导致RTV显著更大,表示这可能是降低螺钉松动风险的一种解决方案。