Suppr超能文献

在具有功能性膝关节定位的机器人辅助全膝关节置换术中,股骨组件的旋转对线在不同膝关节表型之间存在差异,但不影响临床结果。

Femoral component rotational alignment in robotic-assisted total knee arthroplasty with functional knee positioning varies across knee phenotypes without affecting clinical outcomes.

作者信息

Zambianchi Francesco, Bazzan Gabriele, Iorio Vincenzo, Cuoghi Costantini Riccardo, Seracchioli Stefano, Catani Fabio

机构信息

Department of Orthopaedics and Traumatology, Azienda Ospedaliero-Universitaria di Modena, University of Modena and Reggio-Emilia, Modena, Italy.

Department of Orthopaedics and Traumatology, Ospedale Maggiore di Lodi, Lodi, Italy.

出版信息

Knee Surg Sports Traumatol Arthrosc. 2025 Jun 29. doi: 10.1002/ksa.12732.

Abstract

PURPOSE

This retrospective, observational study aimed to investigate the distribution of femoral component rotational alignment among different knee phenotypes and assess the clinical relevance of femoral component rotation variability in patients undergoing image-based robotic-assisted total knee arthroplasty (RA-TKA) performed with functional knee positioning (FP). It was hypothesized that femoral component rotational alignment can change based on preoperative knee phenotypes, without affecting clinical outcomes.

METHODS

A total of 256 patients who underwent image-based RA-TKA with the Mako robotic system at a single centre from February 2020 to March 2022 were included. Preoperative robotic-derived computed tomography (CT) data were gathered to determine the Coronal Plane Alignment of the Knee (CPAK) classification and the axial orientation of the distal femur. Intraoperative data relative to femoral component rotational alignment were collected. At a minimum of 24 months post-operatively, patients were administered the Forgotten Joint Score-12 (FJS-12) and the Knee Injury and Osteoarthritis Outcome Score for Joint Replacement (KOOS-JR). The distribution of femoral component rotation among phenotypes, as well as the relationships between alignment parameters and clinical outcomes, were assessed by means of linear regression models and one-way analysis of variance.

RESULTS

A total of 219 cruciate retaining TKAs were considered for implant positioning assessment. Femoral component rotational alignment varied significantly among different knee phenotypes, ranging from -6.9° internal to 6.6° external rotation with respect to surgical transepicondylar axis. No significant association was found between femoral component rotation and patient-reported outcomes (FJS-12 and KOOS-JR). Three patients (1.4%) underwent RA-TKA revision, while no patello-femoral complications were reported in any of the patients.

CONCLUSIONS

In the setting of image-based RA-TKA performed with FP, the rotational alignment of the femoral component changes significantly among different knee phenotypes. These variations do not affect clinical outcomes at a minimum of 2 years of follow-up and do not result in significant patello-femoral complications.

LEVEL OF EVIDENCE

Level III.

摘要

目的

本回顾性观察研究旨在调查不同膝关节表型中股骨假体旋转对线的分布情况,并评估在基于图像的机器人辅助全膝关节置换术(RA-TKA)中采用功能膝关节定位(FP)时股骨假体旋转变异性的临床相关性。研究假设是股骨假体旋转对线可根据术前膝关节表型发生变化,而不影响临床结果。

方法

纳入2020年2月至2022年3月在单一中心接受基于图像的Mako机器人系统RA-TKA的256例患者。收集术前机器人衍生的计算机断层扫描(CT)数据以确定膝关节冠状面排列(CPAK)分类和股骨远端的轴向方向。收集与股骨假体旋转对线相关的术中数据。术后至少24个月时,对患者进行遗忘关节评分-12(FJS-12)和膝关节损伤与骨关节炎置换结局评分(KOOS-JR)。通过线性回归模型和单因素方差分析评估不同表型中股骨假体旋转的分布情况以及对线参数与临床结果之间的关系。

结果

共对219例保留交叉韧带的全膝关节置换术进行了植入物定位评估。不同膝关节表型之间股骨假体旋转对线差异显著,相对于手术经髁轴,内旋范围为-6.9°至外旋6.6°。未发现股骨假体旋转与患者报告结局(FJS-12和KOOS-JR)之间存在显著关联。3例患者(1.4%)接受了RA-TKA翻修,且所有患者均未报告髌股并发症。

结论

在采用FP进行的基于图像的RA-TKA中,不同膝关节表型之间股骨假体的旋转对线变化显著。这些变化在至少2年的随访中不影响临床结果,也不会导致明显的髌股并发症。

证据级别

三级。