Suppr超能文献

非衍射型增强深度聚焦人工晶状体用于年龄相关性黄斑变性患者的视觉效果。

Visual outcomes with a non-diffractive enhanced depth-of-focus IOL in patients with age-related macular degeneration.

作者信息

Elvira Juan Carlos, Devesa Patricia, Elvira-Giner Belén, Tañá-Sanz Pedro, Orts-Vila Paz, Tañá-Rivero Pedro

机构信息

Oftalvist, Alicante, Spain.

出版信息

Front Med (Lausanne). 2025 Jun 13;12:1505401. doi: 10.3389/fmed.2025.1505401. eCollection 2025.

Abstract

PURPOSE

To evaluate visual function in eyes with age-related macular degeneration (AMD) implanted with a non-diffractive enhanced depth-of-focus (EDOF) intraocular lens (IOL) after cataract surgery.

DESIGN

Prospective, observational, non-randomized clinical study.

METHODS

Twenty-two eyes from 22 patients diagnosed with AMD and cataracts were submitted to standard cataract surgery with a non-diffractive EDOF IOL implantation (AcrySof IQ Vivity). We measured monocular uncorrected and best-corrected-distance visual acuity (UDVA and CDVA), uncorrected- and distance-corrected-intermediate visual acuity (UIVA and DCIVA), uncorrected- and distance-corrected-near visual acuity (UNVA and DCNVA), manifest refractive spherical equivalent (MRSE) and cylinder, monocular defocus curve and patient-reported outcome questionnaires (Catquest-9SF and NEI VFQ-25). Follow-up visits were carried out at 1, 3 and 6 months post-surgery.

RESULTS

At 6 months post-surgery all eyes were within ± 0.50 D with a mean MRSE of -0.19 ± 0.20 D, 95.45% had a refractive cylinder of ≤ 0.50 D with a mean cylinder of -0.24 ± 0.27 D. The mean values of postoperative monocular CDVA, DCIVA, and DCNVA were 0.02 ± 0.08, 0.16 ± 0.11, and 0.26 ± 0.15 logMAR, respectively. The defocus curve showed good visual acuity at distance and intermediate with a depth-of-focus of about 1.60 D. A total of 81.82% of patients did not report any difficulty with their vision in their everyday-life and 86.36% reported being quite satisfied to very satisfied with their current vision. The NEI VFQ-25 showed that all values improved significantly ( < 0.05) after the surgery in the different parameters analyzed except for ocular pain ( = 0.390) and color vision ( = 0.333).

CONCLUSION

The use of a non-diffractive EDOF IOL in AMD eyes with cataracts is a safe and effective surgical approach for visually correcting aphakia, providing good visual acuity at far and intermediate distances. Our outcomes support the use of non-diffractive EDOF IOLs in patients with AMD diagnosed with cataracts aiming to obtain spectacle-independence at far and intermediate distances.

摘要

目的

评估白内障手术后植入非衍射性增强景深(EDOF)人工晶状体(IOL)的年龄相关性黄斑变性(AMD)患者眼睛的视觉功能。

设计

前瞻性、观察性、非随机临床研究。

方法

对22例诊断为AMD和白内障的患者的22只眼睛进行标准白内障手术并植入非衍射性EDOF人工晶状体(AcrySof IQ Vivity)。我们测量了单眼未矫正和最佳矫正远视力(UDVA和CDVA)、未矫正和远距矫正中视力(UIVA和DCIVA)、未矫正和远距矫正近视力(UNVA和DCNVA)、明显屈光球镜等效度(MRSE)和柱镜、单眼散焦曲线以及患者报告的结局问卷(Catquest-9SF和NEI VFQ-25)。术后1、3和6个月进行随访。

结果

术后6个月时,所有眼睛的MRSE均值为-0.19±0.20D,在±0.50D范围内,95.45%的患者柱镜度数≤0.50D,平均柱镜度数为-0.24±0.27D。术后单眼CDVA、DCIVA和DCNVA的平均值分别为0.02±0.08、0.16±0.11和0.26±0.15logMAR。散焦曲线显示在远距和中距具有良好视力,景深约为1.60D。共有81.82%的患者在日常生活中未报告任何视力问题,86.36%的患者报告对其当前视力相当满意至极满意。NEI VFQ-25显示,除眼痛(P=0.390)和色觉(P=0.333)外,手术后视功能在不同参数分析中均有显著改善(P<0.05)。

结论

在患有白内障的AMD患者眼中使用非衍射性EDOF人工晶状体是一种安全有效的手术方法,可用于视力矫正无晶状体眼,在远距和中距提供良好视力。我们的结果支持在诊断为白内障的AMD患者中使用非衍射性EDOF人工晶状体,旨在实现远距和中距无需眼镜。