Díaz-Gómez Sergio, Sankaridurg Padmaja, López-Garrido José A, Burgos-Martínez Mercedes, Carballo-Álvarez Jesús
Faculty of Optics and Optometry, Complutense University of Madrid, Madrid, Spain.
Miranza Centro Oftalmológico Integral (COI), Bilbao, Spain.
Ophthalmic Physiol Opt. 2025 Sep;45(6):1512-1524. doi: 10.1111/opo.13549. Epub 2025 Jun 30.
To evaluate the progression of myopia as assessed by changes in axial length (AL) and spherical equivalent (SE) in Caucasian children wearing extended depth of focus soft contact lenses (CL) compared with distance single-vision spectacles after 3 years.
A total of 96 progressing (at least -0.75 D increase in the previous 12 months) myopic children (aged 6-13 years) with SE ranging from -0.75 to -10.00 D were recruited. Forty-five children were fitted with CL (MYLO), whereas 51 wore spectacles. Cycloplegic refraction was measured with an auto-refractometer and AL with the Zeiss IOLMaster-700 at 6-month intervals. Subjective responses of CL wear were determined using a questionnaire on a scale of 1 (very poor) to 10 (excellent). High-contrast visual acuity (HCVA) was also evaluated.
A total of 43 and 41 children achieved 3 years of wear with CL and spectacles, respectively. Mean change in SE and AL was -0.90 ± 0.36 D and 0.55 ± 0.04 mm in the CL group and -1.64 ± 0.26 D and 0.97 ± 0.03 mm in the spectacle group, respectively (all p < 0.001). The cumulative absolute reduction in axial elongation was 0.42 mm. The difference in SE change was 0.74 D. While 90% of the children wearing CL had an AL increase of ≤0.60 mm, 96% of the spectacle group increased by at least 0.91 mm. Indeed, 50% of the CL group showed myopia progression of at least 0.75 D, whereas all the spectacle group progressed by at least 0.75 D. Subjective responses indicated a mean value ≥9. There was a reduction in HCVA of half a logMAR line with CL compared to spectacles (p < 0.001).
Three years of wear with MYLO CL resulted in clinically significant slower myopia progression compared to the SV spectacle group.
评估与佩戴远距单焦点眼镜相比,佩戴扩展景深软性接触镜(CL)的白种儿童3年后眼轴长度(AL)和等效球镜度(SE)变化所评估的近视进展情况。
共招募了96名近视进展儿童(年龄6 - 13岁),其等效球镜度在-0.75至-10.00 D之间,且在前12个月至少增加了-0.75 D。45名儿童佩戴CL(MYLO),51名儿童佩戴眼镜。每隔6个月使用自动验光仪测量睫状肌麻痹验光,使用蔡司IOLMaster - 700测量眼轴长度。使用一份从1(非常差)到10(优秀)的问卷确定佩戴CL的主观感受。还评估了高对比度视力(HCVA)。
分别有43名和41名儿童佩戴CL和眼镜达到3年。CL组的等效球镜度和眼轴长度的平均变化分别为-0.90±0.36 D和0.55±0.04 mm,眼镜组分别为-1.64±0.26 D和0.97±0.03 mm(所有p < 0.001)。眼轴伸长的累积绝对减少量为0.42 mm。等效球镜度变化的差异为0.74 D。佩戴CL的儿童中有90%的眼轴长度增加≤0.60 mm,眼镜组中有96%的儿童眼轴长度增加至少0.91 mm。实际上,CL组中有50%的儿童近视进展至少为0.75 D,而眼镜组所有儿童近视进展至少为0.75 D。主观感受表明平均值≥9。与眼镜相比,佩戴CL时高对比度视力降低了半个logMAR行(p < 0.001)。
与单焦点眼镜组相比,佩戴MYLO CL三年导致临床上近视进展明显减慢。