人工耳蜗植入儿童镫骨肌电反射阈值(eSRT)的纵向变化

Longitudinal changes in electrical stapedius reflex thresholds (eSRT) in children with cochlear implants.

作者信息

Muigg Franz, Graf Simone, Mair Maria Magdalena, Seebacher Josef, Salloum Hazem, Weichbold Viktor, Schmutzhard Joachim, Zelger Philipp

机构信息

University Hospital for Hearing, Speech & Voice Disorders, Medical University of Innsbruck, Innsbruck, Austria.

Department of Otorhinolaryngology-Head and Neck Surgery, Medical University of Innsbruck, 6020, Innsbruck, Austria.

出版信息

Eur Arch Otorhinolaryngol. 2025 Jul 4. doi: 10.1007/s00405-025-09532-4.

Abstract

STUDY GOAL

The electrically evoked stapedius reflex threshold (eSRT) is widely used as an estimate of the maximum comfort level (MCL) in the fitting of cochlear implants (CI). This study investigated the long-term evolution of the eSRT during a ten-year observation period.

METHODS

Retrospective analysis of fitting map data (charge units [QU] required to evoke the stapedius reflex) obtained from 50 cochlear-implanted ears of 26 children. Time-series statistical methods were employed to examine trends in charge unit (QU) values and their variance, normalized to individual baselines.

RESULTS

The QU time series mean increased significantly within the first six months post-implantation and reached a plateau thereafter. Variance in eSRT decreased significantly over the first five years, with three key turning points identified at six months, 18 months, and 4.25 years, indicating significantly diminishing variation with time.

DISCUSSION

CI fitting schedules should be coordinated with temporal changes in eSRT variance. Frequent fittings in the first 18 months, followed by annual fittings until four years after implantation, seem advisable. After this period, less frequent fittings may be sufficient.

摘要

研究目标

电诱发镫骨肌反射阈值(eSRT)在人工耳蜗(CI)适配中被广泛用作最大舒适度水平(MCL)的评估指标。本研究调查了在十年观察期内eSRT的长期演变情况。

方法

对从26名儿童的50只人工耳蜗植入耳获取的适配图数据(诱发镫骨肌反射所需的电荷单位[QU])进行回顾性分析。采用时间序列统计方法来检查电荷单位(QU)值及其方差的趋势,并将其归一化到个体基线水平。

结果

QU时间序列均值在植入后的前六个月内显著增加,此后达到平稳状态。eSRT的方差在头五年内显著下降,在六个月、18个月和4.25年时确定了三个关键转折点,表明随时间变化的变异显著减少。

讨论

CI适配方案应与eSRT方差的时间变化相协调。在植入后的前18个月内频繁进行适配,随后每年进行一次适配直至植入后四年,似乎是可取的。在此期间之后,减少适配频率可能就足够了。