Suppr超能文献

Indirect auscultatory systolic and diastolic pressures in the anesthetized dog.

作者信息

Wessale J L, Smith L A, Reid M, Janas W, Carter A B, Geddes L A

出版信息

Am J Vet Res. 1985 Oct;46(10):2129-32.

PMID:4062018
Abstract

The auscultatory method was used to obtain indirect systolic and diastolic pressures in 13 dogs anesthetized with either halothane or sodium pentobarbital (30 mg/kg of body weight). Korotkoff sounds were obtained, using a 1-cm (diameter) piezoelectric element cemented to the inner surface of a pediatric cuff (width 5.5 cm) which was placed on a shaved thoracic limb (membrum thoracicum). The signal from the piezoelement was amplified by a differential amplifier (30 to 200 Hz) and a commercially available audio amplifier. Indirect pressure (I) was compared with direct pressure (D) in the brachial, femoral, or carotid artery. The linear regression lines and correlation coefficients (r) for the data were as follows: systolic, I = 0.94 (D) + 1.1, r = 0.98; diastolic, I = 0.99 (D) + 3.2, r = 0.99. The quality of the Korotkoff sounds and the accuracy of the determinations were best in the halothane-anesthetized dogs. These results indicate that indirect auscultatory systolic and diastolic pressures are in excellent agreement with the directly measured pressures.

摘要

文献检索

告别复杂PubMed语法,用中文像聊天一样搜索,搜遍4000万医学文献。AI智能推荐,让科研检索更轻松。

立即免费搜索

文件翻译

保留排版,准确专业,支持PDF/Word/PPT等文件格式,支持 12+语言互译。

免费翻译文档

深度研究

AI帮你快速写综述,25分钟生成高质量综述,智能提取关键信息,辅助科研写作。

立即免费体验