Suppr超能文献

麻醉犬直接和间接血压测量的比较。

Comparison of direct and indirect blood pressure measurements in anesthetized dogs.

作者信息

Gains M J, Grodecki K M, Jacobs R M, Dyson D, Foster R A

机构信息

Department of Pathology, Ontario Veterinary College, University of Guelph.

出版信息

Can J Vet Res. 1995 Jul;59(3):238-40.

Abstract

The precision and accuracy of an indirect oscillometric blood pressure measurement technique (Dinamap 8100) was assessed in 11 anesthetized Beagle dogs weighing 8 to 11.5 kg. Direct blood pressure measurements were made by catheterization of the lingual artery, and simultaneous indirect measurements were determined by placing a cuff over the median artery (midradial area). Blood pressure measurements at 2 different planes of anesthesia (light and deep) were recorded in triplicate. At a light plane of anesthesia, the Dinamap 8100 underestimated diastolic and mean arterial pressure, and at a deep anesthetic plane overestimated systolic pressure. The indirect technique had good repeatability of systolic pressures. Regression analysis for the 2 techniques showed excellent correlation (r = 0.93). The results indicate that the indirect oscillometric blood pressure measurement technique provides a good estimate of systolic, diastolic, and mean arterial pressure in dogs weighing 8-11.5 kg.

摘要

在11只体重8至11.5千克的麻醉比格犬中评估了一种间接示波血压测量技术(Dinamap 8100)的精密度和准确性。通过舌动脉插管进行直接血压测量,并通过在正中动脉(桡骨中部区域)放置袖带进行同步间接测量。在麻醉的2个不同平面(浅麻醉和深麻醉)下的血压测量记录3次。在浅麻醉平面下,Dinamap 8100低估了舒张压和平均动脉压,而在深麻醉平面下高估了收缩压。间接技术的收缩压具有良好的重复性。两种技术的回归分析显示出极好的相关性(r = 0.93)。结果表明,间接示波血压测量技术能很好地估计体重8 - 11.5千克犬的收缩压、舒张压和平均动脉压。

相似文献

3
Evaluation of high-definition and conventional oscillometric blood pressure measurement in anaesthetised dogs using ACVIM guidelines.
J Small Anim Pract. 2010 Jun;51(6):318-24. doi: 10.1111/j.1748-5827.2010.00938.x. Epub 2010 May 10.
10

引用本文的文献

本文引用的文献

2
Indirect mean arterial pressure in the anesthetized dog.
Am J Physiol. 1980 May;238(5):H664-6. doi: 10.1152/ajpheart.1980.238.5.H664.
4
An assessment of the Dinamap 845.对迪纳迈普845的评估。
Anaesthesia. 1984 Mar;39(3):261-7. doi: 10.1111/j.1365-2044.1984.tb07240.x.
5
Measurement of systemic arterial blood pressure.体循环动脉血压的测量。
Vet Clin North Am Small Anim Pract. 1983 May;13(2):321-36. doi: 10.1016/s0195-5616(83)50032-6.
8
Noninvasive measurement of systemic arterial blood pressure in the conscious beagle dog.
Fundam Appl Toxicol. 1988 Jan;10(1):89-97. doi: 10.1016/0272-0590(88)90254-0.
9
Methods for the measurement of blood pressure in conscious rats.
Contrib Nephrol. 1988;60:220-9. doi: 10.1159/000414806.