圆锥细胞对比色觉测试的可重复性

Repeatability of Cone Contrast Color Vision Tests.

作者信息

Hovis Jeffery K, Almustanyir Ali, Glaholt Mackenzie

出版信息

Aerosp Med Hum Perform. 2025 Apr;96(4):287-295. doi: 10.3357/AMHP.6538.2025.

Abstract

INTRODUCTION

New computerized color vision tests are gaining popularity in the aviation community. These tests determine color vision status by measuring chromatic sensitivity and they can effectively classify color vision as normal vs. abnormal. However, little information is available regarding their repeatability. We evaluated the repeatability of two such tests: the Operational Based Visual Assessment Cone Contrast Test (OCCT) and the Rabin Cone Contrast Test (RCCT).

METHODS

A total of 56 subjects with normal color vision and 63 subjects with defective color vision completed both tests twice over 2 sessions. We determined the repeatability for a normal/abnormal result, between-eye differences in thresholds within a session, and between-session results for each eye.

RESULTS

Both tests had excellent repeatability for normal vs. abnormal color vision (i.e., using a cutoff score of 75 Rabin Color Contrast Sensitivity Units). The OCCT also had excellent repeatability for acceptable vs. unacceptable color discrimination (i.e., a cutoff score of 55), whereas the RCCT repeatability was lower. The RCCT's lower repeatability was because the between-eye and between-session Limits of Agreement for the color-defective subjects were approximately ±40 relative sensitivity units. In contrast, the Limits of Agreement for the OCCT ranged from ±10 to ±15.

DISCUSSION

These results reinforce the advantage of using a finer stimulus change when estimating cone thresholds in the clinical setting. Hovis JK, Almustanyir A, Glaholt M. Repeatability of cone contrast color vision tests. Aerosp Med Hum Perform. 2025; 96(4):287-295.

摘要

引言

新型计算机化色觉测试在航空领域越来越受欢迎。这些测试通过测量色觉敏感度来确定色觉状态,并且能够有效地将色觉分为正常和异常。然而,关于它们的可重复性的信息却很少。我们评估了两种这样的测试的可重复性:基于操作的视觉评估视锥细胞对比度测试(OCCT)和拉宾视锥细胞对比度测试(RCCT)。

方法

共有56名色觉正常的受试者和63名色觉有缺陷的受试者在两个阶段完成了这两项测试各两次。我们确定了正常/异常结果的可重复性、同一阶段内两眼阈值的差异以及每只眼睛不同阶段的结果。

结果

对于正常与异常色觉(即使用75拉宾颜色对比度敏感度单位的临界值),这两种测试都具有出色的可重复性。对于可接受与不可接受的颜色辨别(即临界值为55),OCCT也具有出色的可重复性,而RCCT的可重复性较低。RCCT较低的可重复性是因为色觉有缺陷的受试者两眼之间和不同阶段的一致性界限约为±40相对敏感度单位。相比之下,OCCT的一致性界限范围为±10至±15。

讨论

这些结果强化了在临床环境中估计视锥细胞阈值时使用更精细刺激变化的优势。霍维斯JK、阿尔穆斯塔尼伊尔A、格拉霍尔特M。视锥细胞对比度色觉测试的可重复性。航空航天医学与人类表现。2025;96(4):287 - 295。