Mastrangelo Filiberto, Cicciù Marco, Quaresima Raimondo, Scarano Antonio
Department of Clinical and Experimental Medicine, University of Foggia, Via Rovelli n. 60, 77100 Foggia, Italy.
Department of Biomedical and Surgical and Biomedical Sciences, Catania University, 95123 Catania, Italy.
Materials (Basel). 2025 Jul 3;18(13):3165. doi: 10.3390/ma18133165.
In the animal model, we aim to evaluate the bone behavior in two innovative and different laser-treated (L1-L2) titanium implants compared to sandblasted and acid-etched (SBAE) used as control.
A total of twenty-seven dental implants (8.5 × 3.3 mm) used for the study (Sweden & Martina, Due Carraie Padova-Italy) were placed in three Pelibuey female sheep. Implant surface profilometric, contact angle and EDX analysis were detected. After 15, 30 and 90 days, histological, histomorphometric, SEM-EDX analysis and Bone-to-implant Contact (BIC), Dynamic Osseointegration Index (DOI) and Bone Quality Index (BQI) (as Calcium and Phosphorous atomic percentages ratio) were performed.
All surfaces showed relevant profilometric and wettability differences. After 15 days, BIC showed great differences in L2 (42.1 ± 2.6) compared to L1 (5.2 ± 3.1) and SBAE (23.3 ± 3.9) as well as after 30 days (L2 (82.4 ± 2.2), L1 (56.2 ± 1.3) and SBAE (77.3 ± 0.4)). After 90 days, relevant lower BIC values were detected in L1 (68.4 ± 0.2) compared to L2 (86.4 ± 0.1) and SBAE (86.2 ± 0.6). The DOI showed higher rates of bone growth in L2 after 15 (DOI = 2.81) and 30 days (DOI = 2.83), compared to L1 (DOI = 0.38, DOI = 3.40) and SBAE (DOI = 1.55, DOI = 2.58). The DOI drastic slowdown in SBAE (0.96), L1 (0.76), and L2 (0.95) confirmed the Early Osseointegration (EO) as a crucial phase. Moreover, before loading, the lower global BQI in L1 (Ca 44.43 ± 0.08-P 46.14 ± 5.15) and SBAE (Ca 45.31 ± 2.08-P 48.28 ± 1.12) compared to L2 (Ca 79.81 ± 2.08-P 81.85 ± 3.14) allows to assert that osseointegration process and bone healing could not be considered complete if compared to the native bone.
The BIC, DOI, and BQI results showed that osseointegration is a dynamic process, confirming the crucial role of surface characteristics able to influence it, especially the early osseointegration (EO) phase. The short-time L2 implants' higher bone quantity and quality results, compared to L1 and SBAE, suggested the fundamental role of this innovative laser-obtained surface in "secondary stability" and predictable long-term clinical outcomes.
在动物模型中,我们旨在评估两种创新且不同的经激光处理(L1-L2)的钛植入物与用作对照的喷砂和酸蚀(SBAE)植入物相比的骨行为。
总共27颗用于该研究的牙科植入物(8.5×3.3毫米)(瑞典&玛蒂娜,意大利帕多瓦杜埃卡拉伊)被植入三只佩利布埃母羊体内。检测植入物表面轮廓测量、接触角和能谱分析。在15天、30天和90天后,进行组织学、组织形态计量学、扫描电子显微镜-能谱分析以及骨与植入物接触(BIC)、动态骨结合指数(DOI)和骨质量指数(BQI)(作为钙和磷原子百分比比率)分析。
所有表面均显示出明显的轮廓测量和润湿性差异。15天后,与L1(5.2±3.1)和SBAE(23.3±3.9)相比,L2的BIC显示出很大差异(42.1±2.6),30天后也是如此(L2(82.4±2.2),L1(56.2±1.3)和SBAE(77.3±0.4))。90天后,与L2(86.4±0.1)和SBAE(86.2±0.6)相比,L1的BIC值明显较低(68.4±0.2)。与L1(DOI = 0.38,DOI = 3.40)和SBAE(DOI = 1.55,DOI = 2.58)相比,L2在15天(DOI = 2.81)和30天(DOI = 2.83)后的DOI显示出更高的骨生长速率。SBAE(0.96)、L1(0.76)和L2(0.95)的DOI急剧下降证实了早期骨结合(EO)是一个关键阶段。此外,在加载前,与L2(钙79.81±2.08 - 磷81.85±3.14)相比,L1(钙44.43±0.08 - 磷46.14±5.15)和SBAE(钙45.31±2.08 - 磷48.28±1.12)的整体BQI较低,这表明与天然骨相比,骨结合过程和骨愈合不能被认为是完整的。
BIC、DOI和BQI结果表明骨结合是一个动态过程,证实了能够影响它的表面特性的关键作用,特别是早期骨结合(EO)阶段。与L1和SBAE相比,短期L2植入物在骨量和质量方面的更高结果表明这种创新的激光获得表面在“二级稳定性”和可预测的长期临床结果中具有重要作用。