Suppr超能文献

利用胎儿肾长与其他生物测量指标比较估算孕周

Estimation of Gestational Age by Using Fetal Kidney Length in Comparison with Other Biometric Indices.

作者信息

Tulasi Sushmitha Alias, Sarvesh R, Shriram T

机构信息

Department of Radiodiagnosis, Aarupadai Veedu Medical College and Hospital, Puducherry, India.

Department of Radiodiagnosis, ACS Medical College and Hospital, Chennai, Tamil Nadu, India.

出版信息

J Pharm Bioallied Sci. 2025 Jun;17(Suppl 2):S1861-S1864. doi: 10.4103/jpbs.jpbs_576_25. Epub 2025 Jun 18.

Abstract

BACKGROUND

Fetal kidney length (FKL) has emerged as a promising alternative, with a strong correlation to gestational age, particularly in the third trimester.

AIM

To determine the accuracy of FKL in estimating fetal gestational age by ultrasonography and comparing its efficacy with other biometric indices.

MATERIALS AND METHODS

A comparative observational study was conducted at Aarupadai Veedu Medical College and Hospital, Puducherry, involving 110 antenatal women with singleton pregnancies between 20 and 40 weeks of gestation. Ultrasound examinations were performed using a Mindray DC 80 machine with a 3.5-5 MHz curvilinear probe. Gestational age was estimated using FKL and compared with standard biometric indices. Pearson correlation analysis and independent -tests were performed using SPSS version 26.0, with significance set at < 0.05.

RESULTS

A significant positive correlation was observed between FKL and gestational age ( = 0.975, < 0.001). The mean FKL showed a consistent linear increase with advancing gestational age, comparable to traditional biometric indices such as head circumference and abdominal circumference. Right and left kidney lengths exhibited similar correlations, reinforcing the reliability of FKL in estimating gestational age.

CONCLUSION

FKL is a reliable parameter for gestational age estimation, particularly in the third trimester. Its strong correlation with standard biometric indices supports its use as an adjunct in prenatal ultrasound assessments, especially in cases where conventional measurements are inconclusive.

摘要

背景

胎儿肾长(FKL)已成为一种有前景的替代指标,与孕周密切相关,尤其是在孕晚期。

目的

通过超声检查确定FKL估计胎儿孕周的准确性,并将其与其他生物测量指标的有效性进行比较。

材料与方法

在本地治里的阿鲁帕代维杜医学院和医院进行了一项比较观察性研究,纳入了110例孕周在20至40周之间的单胎妊娠孕妇。使用迈瑞DC 80机器和3.5 - 5 MHz的曲线探头进行超声检查。使用FKL估计孕周,并与标准生物测量指标进行比较。使用SPSS 26.0版本进行Pearson相关分析和独立样本t检验,显著性设定为P < 0.05。

结果

观察到FKL与孕周之间存在显著正相关(r = 0.975,P < 0.001)。平均FKL随孕周增加呈一致的线性增加,与头围和腹围等传统生物测量指标相当。左右肾长表现出相似的相关性,加强了FKL在估计孕周方面的可靠性。

结论

FKL是估计孕周的可靠参数,尤其是在孕晚期。它与标准生物测量指标的强相关性支持其在产前超声评估中作为辅助手段使用,特别是在传统测量结果不确定的情况下。

相似文献

本文引用的文献

4
Quantitative characterization of the growth of the fetal kidney.胎儿肾脏生长的定量表征
J Clin Ultrasound. 1983 Sep;11(7):349-56. doi: 10.1002/jcu.1870110702.
6
Growth of the fetal biparietal diameter during normal pregnancy.正常孕期胎儿双顶径的生长情况。
J Obstet Gynaecol Br Commonw. 1971 Jun;78(6):513-9. doi: 10.1111/j.1471-0528.1971.tb00309.x.

文献检索

告别复杂PubMed语法,用中文像聊天一样搜索,搜遍4000万医学文献。AI智能推荐,让科研检索更轻松。

立即免费搜索

文件翻译

保留排版,准确专业,支持PDF/Word/PPT等文件格式,支持 12+语言互译。

免费翻译文档

深度研究

AI帮你快速写综述,25分钟生成高质量综述,智能提取关键信息,辅助科研写作。

立即免费体验