Suppr超能文献

外侧半月板至腘肌腱的全内缝合固定:生物力学评估

All-Inside Suture Fixation of the Lateral Meniscus to the Popliteal Tendon: A Biomechanical Evaluation.

作者信息

Gräber Sina, Becker Josephine, Jasina Andrzej, Sass Jan-Oliver, Hembus Jessica, Bader Rainer, Pourostad Parisa, Tischer Thomas, Lutter Christoph

机构信息

Department of Orthopaedics, University Medical Center, Rostock, Germany.

Klinik für Orthopädie und Unfallchirurgie Malteser Waldkrankenhaus St. Marien, Erlangen, Germany.

出版信息

Orthop J Sports Med. 2025 Jul 15;13(7):23259671251338306. doi: 10.1177/23259671251338306. eCollection 2025 Jul.

Abstract

BACKGROUND

Lesions of the posterolateral parts of the lateral meniscus are commonly treated with all-inside suture repair. The popliteal tendon is one of the few anatomic structures available to attach these anchor systems. However, this method is controversial and its biomechanical effects are unknown.

HYPOTHESIS

Suture fixation of the lateral meniscus to the popliteal tendon significantly affects the mobility of both structures involved.

STUDY DESIGN

Descriptive laboratory study.

METHODS

Six fresh-frozen human knee specimens were tested using a biaxial servohydraulic testing machine. Ten loading cycles of ±10° internal-external rotation were performed under 100 N axial load and 30° joint flexion. The popliteal muscle was constantly loaded with 44 N. A 3-dimensional optical measurement system recorded the movement of the lateral meniscus, popliteal tendon, and lateral femoral condyle. The resultant torque was also measured. Each knee joint was tested without and with suture fixation of the lateral meniscus to the popliteal tendon. All-inside suture repairs were performed under arthroscopic control.

RESULTS

Fixation of the lateral meniscus to the popliteal tendon resulted in a significant reduction in both (absolute and relative) movement of the components involved. On average, the absolute displacement of the lateral meniscus decreased by 34.3% (1.2 mm; < .001) and that of the popliteal tendon proximal to the suture by 18.8% (0.3 mm; = .02). There was a 23.5% (0.8 mm; < .001) reduction in relative movement between the lateral femoral condyle and lateral meniscus, a 17.1% (0.6 mm; = .004) reduction between the lateral femoral condyle and popliteal tendon distal to the suture, and a 25.0% (0.7 mm; < .001) reduction between the lateral meniscus and popliteal tendon proximal to the suture. Regarding the measured torque, a significant reduction of 2.0 Nm (18.2%; = .04) was measured for femoral internal rotation.

CONCLUSION

All-inside suture fixation of the lateral meniscus to the popliteal tendon shows significant biomechanical effects.

CLINICAL RELEVANCE

Our results suggest increased tension on the suture with possible implications for meniscal healing. These findings may require adaptation of postoperative management, considering more restrictive treatments or resorbable suture anchors.

摘要

背景

外侧半月板后外侧部分损伤通常采用全内缝合修复治疗。腘肌腱是可用于固定这些锚钉系统的少数解剖结构之一。然而,这种方法存在争议,其生物力学效应尚不清楚。

假设

将外侧半月板缝合固定于腘肌腱会显著影响所涉及的两个结构的活动度。

研究设计

描述性实验室研究。

方法

使用双轴伺服液压试验机对6个新鲜冷冻的人体膝关节标本进行测试。在100 N轴向载荷和30°关节屈曲下进行10个±10°内-外旋转的加载循环。腘肌持续加载44 N。三维光学测量系统记录外侧半月板、腘肌腱和股骨外侧髁的运动。同时测量合成扭矩。每个膝关节在外侧半月板未缝合固定和缝合固定于腘肌腱的情况下进行测试。全内缝合修复在关节镜控制下进行。

结果

将外侧半月板固定于腘肌腱导致所涉及组件的(绝对和相对)运动均显著减少。平均而言,外侧半月板的绝对位移减少了34.3%(1.2 mm;P <.001),缝合近端腘肌腱的绝对位移减少了18.8%(0.3 mm;P = 0.02)。股骨外侧髁与外侧半月板之间的相对运动减少了23.5%(0.8 mm;P <.001),股骨外侧髁与缝合远端腘肌腱之间的相对运动减少了17.1%(0.6 mm;P = 0.004),外侧半月板与缝合近端腘肌腱之间的相对运动减少了25.0%(0.7 mm;P <.001)。关于测量的扭矩,股骨内旋时测量到显著减少2.0 Nm(18.2%;P = 0.04)。

结论

外侧半月板全内缝合固定于腘肌腱显示出显著的生物力学效应。

临床意义

我们的结果表明缝合线上的张力增加,可能对半月板愈合有影响。考虑到更严格的治疗方法或可吸收缝合锚钉,这些发现可能需要调整术后管理。

https://cdn.ncbi.nlm.nih.gov/pmc/blobs/e2e8/12264396/f36da5b12d43/10.1177_23259671251338306-fig1.jpg

文献检索

告别复杂PubMed语法,用中文像聊天一样搜索,搜遍4000万医学文献。AI智能推荐,让科研检索更轻松。

立即免费搜索

文件翻译

保留排版,准确专业,支持PDF/Word/PPT等文件格式,支持 12+语言互译。

免费翻译文档

深度研究