Mahmoudkhani Mohammadreza, Alizadeh Fatemeh, Karimizadeh Ardakani Mohammad, Fathi Zahra
Department of Sport Injuries and Corrective Exercises, Faculty of Physical Education and Sport Science, University of Tehran, Tehran, Iran.
Physiother Theory Pract. 2025 Aug;41(8):1694-1702. doi: 10.1080/09593985.2024.2444386. Epub 2024 Dec 20.
The Upper Quarter Y Balance Test (YBT-UQ) assesses upper limb dynamic balance in able-bodied individuals but lacks a reliable version for those with disabilities.
This study aimed to introduce a modified YBT-UQ (mYBT-UQ) for physically impaired individuals (PI) and establish its validity and reliability.
The study involved 33 male athletes aged 18-55, divided into three equal groups: able-bodied, spinal cord injury with trunk control (SCI), and below-the-knee amputation (BKA). To ensure test validity, able-bodied athletes completed both tests. Test-retest reliability was evaluated by repeating the mYBT-UQ seven days after the first test by PI groups. The validity was assessed using the Pearson correlation and Bland-Altman plot. The intraclass correlation coefficient (ICC) (2,1), standard error of measurement (SEM), and the minimal detectable change with 95% confidence (MDC95%) were calculated to assess relative and absolute reliability.
There were significant differences and excellent relationships between YBT-UQ and the mYBT-UQ. Also, the Bland-Altman plot showed minimal bias and an acceptable range of agreement. In athletes with BKA, the ICC (2,1) was above 0.90 for both limbs. The SEM ranged from 2.4%-2.7%, and MDC95% ranged from 6.7%-7.5%. In athletes with SCI, the ICC (2,1) ranged from 0.72-0.80. The SEM ranged from 3.1%-3.2% and MDC95% ranged from 8.6%-8.9%.
The results indicate that the mYBT-UQ is a reliable test to assess upper quarter dynamic balance in athletes with SCI and BKA. However, regarding the small sample size of the study, there is a need to conduct other research to establish the validity of the test.
上肢Y平衡测试(YBT-UQ)用于评估健全个体的上肢动态平衡,但缺乏适用于残疾人士的可靠版本。
本研究旨在为身体有损伤的个体(PI)引入改良的YBT-UQ(mYBT-UQ),并确定其有效性和可靠性。
该研究纳入了33名年龄在18至55岁之间的男性运动员,分为三个相等的组:健全组、有躯干控制能力的脊髓损伤组(SCI)和膝下截肢组(BKA)。为确保测试的有效性,健全运动员完成了两项测试。PI组在首次测试七天后重复进行mYBT-UQ,以评估重测可靠性。使用Pearson相关性和Bland-Altman图评估有效性。计算组内相关系数(ICC)(2,1)、测量标准误差(SEM)和95%置信度下的最小可检测变化(MDC95%),以评估相对和绝对可靠性。
YBT-UQ与mYBT-UQ之间存在显著差异和良好关系。此外,Bland-Altman图显示偏差极小且一致性范围可接受。在BKA运动员中,双侧ICC(2,1)均高于0.90。SEM范围为2.4%-2.7%,MDC95%范围为6.7%-7.5%。在SCI运动员中,ICC(2,1)范围为0.72-0.80。SEM范围为3.1%-3.2%,MDC95%范围为8.6%-8.9%。
结果表明,mYBT-UQ是评估SCI和BKA运动员上肢动态平衡的可靠测试。然而,鉴于本研究样本量较小,需要进行其他研究以确定该测试的有效性。