Effect of Mouse (Mus musculus) Sex and C57BL/6 Substrain on Sensitivity to Isoflurane and Ketamine-Xylazine-Acepromazine Anesthesia.

作者信息

Tuohy Katharine P, Tynan Anila R, Gerisma Jovannah N, Marx James O

机构信息

1University Laboratory Animal Resources, Pathobiology Department, School of Veterinary Medicine, University of Pennsylvania, Philadelphia, Pennsylvania.

2College of Veterinary Medicine, Washington State University, Pullman, Washington; and.

出版信息

J Am Assoc Lab Anim Sci. 2025 Jun 1:1-10. doi: 10.30802/AALAS-JAALAS-25-038.

Abstract

Anesthesia is commonly performed with mice in the research setting. Standard doses of anesthetic drugs are typically recommended, without customization to strain, substrain, or sex. The purpose of this study was to evaluate C57BL/6 substrain and sex differences in response to isoflurane and ketamine/xylazine/acepromazine (KXA) injectable anesthesia. Female and male C57BL/6NTac, C57BL/6J, C57BL6/6NHsd, and C57BL/6NCrl mice were sourced from 4 different vendors. Isoflurane anesthesia trials were performed with a subset of the mice (n = 24) to determine the minimum alveolar concentration (MAC). Loss of righting reflex, total loss of righting time, time to loss of pedal withdrawal reflex, and total time at surgical plane were evaluated for mice (n = 64) administered 100 mg/kg ketamine, 10 mg/kg xylazine, and 1 mg/kg acepromazine by intraperitoneal injection. Heart rate, respiratory rate, and hemoglobin oxygen saturation (SpO2) were monitored throughout each anesthetic event. Isoflurane MAC was not affected by sex or substrain. In the KXA trials, male mice exhibited a longer duration of loss of righting reflex and remained at a surgical plane of anesthesia significantly longer than the female mice. No significant differences in substrain were detected in the depth or duration of anesthesia. Evaluation of physiologic parameters revealed differences in heart rate between substrains, with C57BL/6NHsd mice exhibiting significantly lower heart rates than the other 3 substrains during both isoflurane and KXA anesthesia. C57BL/6J mice had the highest heart rates during KXA anesthesia. These heart rate differences can impact clinical monitoring practices and are important to consider when selecting strains for study models, especially for cardiovascular studies. In conclusion, the male C57BL/6 mice exhibited a longer duration of anesthesia in response to KXA, while no substrain differences were detected for anesthetic depth or duration of either isoflurane or KXA anesthesia.

摘要

在研究环境中,通常对小鼠实施麻醉。一般推荐使用标准剂量的麻醉药物,而不根据品系、亚系或性别进行调整。本研究的目的是评估C57BL/6亚系以及性别对异氟烷和氯胺酮/赛拉嗪/乙酰丙嗪(KXA)注射麻醉的反应差异。雌性和雄性C57BL/6NTac、C57BL/6J、C57BL6/6NHsd和C57BL/6NCrl小鼠来自4个不同的供应商。对一部分小鼠(n = 24)进行异氟烷麻醉试验,以确定最低肺泡浓度(MAC)。对通过腹腔注射给予100 mg/kg氯胺酮、10 mg/kg赛拉嗪和1 mg/kg乙酰丙嗪的小鼠(n = 64),评估其翻正反射消失、翻正总时间、足趾退缩反射消失时间以及处于手术麻醉平面的总时间。在每次麻醉过程中持续监测心率、呼吸频率和血红蛋白氧饱和度(SpO2)。异氟烷MAC不受性别或亚系的影响。在KXA试验中,雄性小鼠翻正反射消失的持续时间更长,并且在手术麻醉平面停留的时间明显长于雌性小鼠。在麻醉深度或持续时间方面,未检测到亚系之间存在显著差异。生理参数评估显示,不同亚系之间心率存在差异,在异氟烷和KXA麻醉期间,C57BL/6NHsd小鼠的心率显著低于其他3个亚系。在KXA麻醉期间,C57BL/6J小鼠的心率最高。这些心率差异会影响临床监测实践,在为研究模型选择品系时,尤其是心血管研究时,需要考虑这些差异。总之,雄性C57BL/6小鼠对KXA的麻醉持续时间更长,而异氟烷或KXA麻醉的深度或持续时间在亚系之间未检测到差异。

文献检索

告别复杂PubMed语法,用中文像聊天一样搜索,搜遍4000万医学文献。AI智能推荐,让科研检索更轻松。

立即免费搜索

文件翻译

保留排版,准确专业,支持PDF/Word/PPT等文件格式,支持 12+语言互译。

免费翻译文档

深度研究

AI帮你快速写综述,25分钟生成高质量综述,智能提取关键信息,辅助科研写作。

立即免费体验