Suppr超能文献

II类复合树脂直接修复与间接修复的临床比较:一项为期12个月的前瞻性随访研究。

Clinical comparison of direct and indirect class II composite restorations: a prospective 12-month follow-up study.

作者信息

Incekara Mürşide Süheda, Karadas Muhammet

机构信息

Department of Restorative Dentistry, Recep Tayyip Erdoğan University, Rize, Turkey.

出版信息

BMC Oral Health. 2025 Jul 19;25(1):1217. doi: 10.1186/s12903-025-06604-z.

Abstract

BACKGROUND

This study evaluated the clinical performance of posterior restorations made with direct and indirect composite materials.

METHODS

In 74 participants, 79 class II cavities were restored using direct composite (Filtek Ultimate) and indirect composite (Crea.lign) materials. Indirect composite restorations were placed to cavity preparations when the isthmus width exceeded two-thirds of the intercuspal distance or teeth had a cuspal loss. Evaluations were conducted using modified World Dental Federation criteria during the first week and at 6 and 12 months. The data were analyzed statistically using Fisher's exact test and chi-square tests.

RESULTS

After 12 months, 58 restorations were evaluated in 54 participants. None of the evaluation criteria showed significant differences between Filtek Ultimate and Crea.lign restorations (p > 0.05). At the 12-month, slight marginal discoloration was found in one Filtek Ultimate and two Crea.lign restorations (p > 0.05). Small marginal gaps were observed in two of the Crea.lign restorations. Post-operative sensitivity was detected within one week for six (13.9%) Filtek Ultimate and three (8.3%) Crea.lign restorations, with no significant difference between the two materials (p = 0.298).

CONCLUSION

At the 12-month evaluation, indirect and direct composite resin materials showed similar clinical performance. Crea.lign indirect composite material demonstrated acceptable clinical performance in large class II cavities, both with and without cuspal loss.

TRIAL REGISTRATION

Retrospectively registered on NCT06667271. Data of registration: 30 October 2024.

摘要

背景

本研究评估了使用直接和间接复合材料制作的后牙修复体的临床性能。

方法

在74名参与者中,使用直接复合材料(Filtek Ultimate)和间接复合材料(Crea.lign)修复了79个II类洞。当峡部宽度超过牙尖间距的三分之二或牙齿有牙尖缺失时,使用间接复合材料进行修复。在第一周、6个月和12个月时,使用改良的世界牙科联盟标准进行评估。使用Fisher精确检验和卡方检验对数据进行统计学分析。

结果

12个月后,对54名参与者的58个修复体进行了评估。Filtek Ultimate和Crea.lign修复体之间的所有评估标准均无显著差异(p>0.05)。在12个月时,在一个Filtek Ultimate修复体和两个Crea.lign修复体中发现了轻微的边缘变色(p>0.05)。在两个Crea.lign修复体中观察到小的边缘间隙。在术后一周内,6个(13.9%)Filtek Ultimate修复体和3个(8.3%)Crea.lign修复体检测到术后敏感性,两种材料之间无显著差异(p=0.298)。

结论

在12个月的评估中,间接和直接复合树脂材料显示出相似的临床性能。Crea.lign间接复合材料在有或无牙尖缺失的大型II类洞中均表现出可接受的临床性能。

试验注册

追溯注册于NCT06667271。注册数据:2024年10月30日。

文献AI研究员

20分钟写一篇综述,助力文献阅读效率提升50倍。

立即体验

用中文搜PubMed

大模型驱动的PubMed中文搜索引擎

马上搜索

文档翻译

学术文献翻译模型,支持多种主流文档格式。

立即体验