Abstract

Coronary angiographic and scintigraphic (using 201Tl) studies in 139 patients with verified diagnosis of chronic coronary heart disease demonstrated high sensitivity (85.6%) of myocardial perfusion scintigraphy with respect to detecting disorders of myocardial blood supply due to the stenosis of major coronary arteries and microcirculation disorders. False negative scintigraphic results in the screening for perfusion defects are commonly due to the shortcomings of semiquantitative assessment of the scintigrams.

摘要

对139例确诊为慢性冠心病的患者进行的冠状动脉造影和闪烁扫描(使用铊-201)研究表明,心肌灌注闪烁扫描在检测主要冠状动脉狭窄和微循环障碍所致心肌供血紊乱方面具有高敏感性(85.6%)。灌注缺损筛查中闪烁扫描的假阴性结果通常归因于闪烁图半定量评估的缺陷。