Abstract

A study was made of change of the spectrum (spectral transformation) of x-ray radiation while passing through the soft tissue. Thirty-two depth spectra computed by the Monte-Carlo method and 16 experimentally measured spectra including 9 depth spectra taken from literature, were analysed. A method of the calculation of an absorbed dose in the red bone marrow with account of spectral transformation was described. It was shown that neglect of this factor caused regular underestimation of the assessment of medullary doses, patients were exposed to, during x-ray procedures. The error can reach 40% for doses at local points of the red bone marrow and 1-7% for mean medullary doses with regard to the type of x-ray procedure and regimen of its performance.

摘要

对X射线辐射穿过软组织时的光谱变化(光谱转换)进行了研究。分析了通过蒙特卡罗方法计算得到的32个深度光谱以及16个实验测量光谱,其中包括9个从文献中获取的深度光谱。描述了一种考虑光谱转换来计算红骨髓吸收剂量的方法。结果表明,忽略这一因素会导致在X射线检查过程中对患者所受髓质剂量评估的系统性低估。根据X射线检查类型及其执行方案,红骨髓局部点剂量的误差可达40%,平均髓质剂量的误差为1 - 7%。