Hemashree J, Padmanabhan Sridevi
Department of Orthodontics & Dentofacial Orthopedics, Sri Ramachandra Institute of Higher Education and Research, Chennai, India.
Department of Orthodontics & Dentofacial Orthopaedics Associate Dean Research, Sri Ramachandra Institute of Higher Education and Research, Chennai, India.
Sci Rep. 2025 Jul 21;15(1):26474. doi: 10.1038/s41598-025-11709-0.
To assess the long term effects of zinc oxide (ZnO) nanoparticle coated elastomeric modules on S. mutans concentration and enamel mineralization among orthodontic patients over a period of one year. A total of 16 patients were recruited for this study. Either the left or right maxillary lateral incisor received the coated module. Group I : ZnO coated elastomeric modules (N = 16); Group II: Non-coated elastomeric modules (N = 16). S. mutans in plaque was assessed at the end of 3 months and one year using Rt -PCR. Enamel mineralization was assessed by laser fluorescence at the end of one year. Integrity of the ZnO nanoparticle coating over a period of one month on a weekly basis was also assessed. Independent t-test was done to find the significant difference between the bivariate samples and intra-group comparison was done using paired t-test. Pearson's correlation was done to determine the relationship between the variables. For all the statistical tests, p < 0.05 was considered to be statistically significant. S. mutans concentration at the end of three months and one year was higher in the non-coated group compared to the coated group but it was statistically significant only at the end of one year (p value = 0.032). Laser fluorescence values was higher for the non-coated group compared to the coated group which showed statistical significance (p = 0.020). ZnO coating of the modules showed evidence of disintegration of the coating after two weeks, with further deterioration of the coating at the end of one month. As elastomeric modules are changed periodically, this appears to be a viable option, especially since the nanoparticle release would be around the most common area of plaque retention.
为评估氧化锌(ZnO)纳米颗粒涂层弹性模块对正畸患者一年内变形链球菌浓度和牙釉质矿化的长期影响。本研究共招募了16名患者。上颌左侧或右侧侧切牙使用涂层模块。第一组:ZnO涂层弹性模块(N = 16);第二组:未涂层弹性模块(N = 16)。在3个月和1年结束时,使用逆转录聚合酶链反应(Rt -PCR)评估菌斑中的变形链球菌。在1年结束时,通过激光荧光评估牙釉质矿化。还每周评估ZnO纳米颗粒涂层在1个月内的完整性。采用独立t检验来发现双变量样本之间的显著差异,并使用配对t检验进行组内比较。进行Pearson相关性分析以确定变量之间的关系。对于所有统计检验,p < 0.05被认为具有统计学意义。与涂层组相比,未涂层组在3个月和1年结束时的变形链球菌浓度更高,但仅在1年结束时具有统计学意义(p值 = 0.032)。未涂层组的激光荧光值高于涂层组,具有统计学意义(p = 0.020)。模块的ZnO涂层在两周后显示出涂层解体的迹象,在1个月末涂层进一步恶化。由于弹性模块会定期更换,这似乎是一个可行的选择,特别是因为纳米颗粒释放将围绕菌斑滞留最常见的区域。