全国性网络中极早产儿动脉导管未闭综合超声心动图评估的可靠性:一项前瞻性观察研究。

Reliability of comprehensive echocardiography evaluation of patent ductus arteriosus among extremely preterm neonates across a national network: A prospective observational study.

作者信息

Weisz Dany E, Thomas Laura, Ye Xiang Y, Mertens Luc, Lapointe Anie, Villeneuve Andréanne, Altit Gabriel, Lalitha Renjini, Ben Fadel Nadya, Jacob George, Louis Deepak, Bhattacharya Soume, Soraisham Amuchou, Hébert Audrey, Mitra Souvik, Hyderi Abbas, Ting Joseph Y, Castaldo Michael, Surak Aimann, Deshpande Poorva, Elsayed Yasser, Jasani Bonny, Nissimov Sagee, Zhu Faith, Shah Prakesh, Jain Amish

机构信息

Newborn and Developmental Paediatrics, Sunnybrook Health Sciences Centre, Toronto, Ontario, Canada.

Department of Paediatrics, University of Toronto, Toronto, Ontario, Canada.

出版信息

J Neonatal Perinatal Med. 2025 Jul 24;18(5):19345798251349744. doi: 10.1177/19345798251349744.

Abstract

BackgroundPrior studies on the reliability of targeted neonatal echocardiography (TNE) among extremely low gestational age neonates (ELGANs) with a patent ductus arteriosus (PDA) have been limited to evaluation of pre-defined images by a small set of study observers. The objective of this study was to investigate the interobserver reliability of comprehensive echocardiography measures of PDA size/shunt volume and ventricular performance among TNE-neonatologists in a large national network.MethodsWe conducted a prospective observational study. TNEs performed for the evaluation of PDA among ELGANs were analyzed by TNE-neonatologists from the Canadian TNE Consortium. Analyses were conducted via an interactive videoconferencing platform offering full remote control to the review software. Reliability for continuous measures was evaluated using the intraclass correlation coefficient (ICC) and coefficient of variation. The kappa statistic was used to evaluate the interobserver reliability of categorical parameters.ResultsReliability was excellent among indices of PDA size and gradient (ICC≥0.91) and good-to-excellent among most indices of left ventricular (LV) size and output (ICC≥0.79, except for LV end-systolic volume and left atrium to aortic root ratio). There was substantial to near-complete agreement on PDA shunt direction and diastolic flow abnormalities in the abdominal aorta and systemic arteries (kappa ≥0.78). However, reliability for measures of LV systolic and diastolic performance was variable with ICC range 0.21-0.95, though with low coefficient of variation (<15%).ConclusionsInterobserver reliability for most TNE measures of PDA size, gradient, shunt volume, and LV dimensions and function is good-to-excellent, supporting the validity of incorporating these indices in prospective multicenter research.

摘要

背景

先前关于胎龄极小的新生儿(ELGANs)动脉导管未闭(PDA)的靶向新生儿超声心动图(TNE)可靠性的研究仅限于少数研究观察者对预定义图像的评估。本研究的目的是在一个大型全国性网络中,调查TNE新生儿科医生对PDA大小/分流体积和心室功能的综合超声心动图测量的观察者间可靠性。

方法

我们进行了一项前瞻性观察研究。加拿大TNE联盟的TNE新生儿科医生分析了为评估ELGANs中的PDA而进行的TNE检查。分析通过一个交互式视频会议平台进行,该平台为审查软件提供完全远程控制。使用组内相关系数(ICC)和变异系数评估连续测量的可靠性。kappa统计量用于评估分类参数的观察者间可靠性。

结果

PDA大小和梯度指标的可靠性极佳(ICC≥0.91),左心室(LV)大小和输出的大多数指标的可靠性良好至极佳(ICC≥0.79,LV收缩末期容积和左心房与主动脉根比率除外)。在PDA分流方向以及腹主动脉和体循环动脉的舒张期血流异常方面存在实质性至几乎完全一致(kappa≥0.78)。然而,LV收缩和舒张功能测量的可靠性各不相同,ICC范围为0.21 - 0.95,尽管变异系数较低(<15%)。

结论

对于PDA大小、梯度、分流体积以及LV尺寸和功能的大多数TNE测量,观察者间可靠性良好至极佳,这支持了将这些指标纳入前瞻性多中心研究的有效性。

https://cdn.ncbi.nlm.nih.gov/pmc/blobs/4404/12344214/5c06e515016e/10.1177_19345798251349744-fig1.jpg