Wong P C, Hey Y, Fowler J S
Clin Chim Acta. 1979 Nov 15;99(1):43-51. doi: 10.1016/0009-8981(79)90138-4.
A new fluorimetric method to assay HGPRT (hypoxanthine-guanine phosphoribosyl transferase, EC 2.4.2.8) from human red cell lysates using 6MP (6-mercaptopurine) as substrate is described. This assay is compared with an existing spectrophotometric method using hypoxanthine as substrate. Precision, sensitivity limits and kinetic differences of these assays are reported.
描述了一种新的荧光测定法,该方法使用6-巯基嘌呤(6MP)作为底物,从人红细胞裂解物中测定次黄嘌呤-鸟嘌呤磷酸核糖基转移酶(HGPRT,EC 2.4.2.8)。将该测定法与现有的以次黄嘌呤为底物的分光光度法进行了比较。报告了这些测定法的精密度、灵敏度极限和动力学差异。