TDK Silmee W22与ActiGraph wGT3X-BT在估算自由生活成年人每日步数及中度至剧烈身体活动方面的一致性:比较研究

Agreement Between TDK Silmee W22 and ActiGraph wGT3X-BT for Estimating Daily Step Counts and Moderate to Vigorous Physical Activity in Free-Living Adults: Comparative Study.

作者信息

Shimura Hiroko, Okada Shinpei, Maruo Kazushi, Daimaru Kaori, Deguchi Naoki, Fujiwara Yoshinori, Sasai Hiroyuki

机构信息

Research Team for Promoting Independence and Mental Health, Tokyo Metropolitan Institute for Geriatrics and Gerontology, Tokyo, Japan.

Department of Liberal Arts, Tokyo University of Technology, 1404-1 Katakura, Hachioji, Tokyo, 192-0982, Japan, 81 42-637-2084.

出版信息

JMIR Form Res. 2025 Jul 30;9:e64602. doi: 10.2196/64602.

Abstract

BACKGROUND

Wearable Internet of Things (IoT) devices are powerful tools for remotely collecting intensive longitudinal data. The TDK Silmee W22, a wristband-type wearable IoT device with a built-in 3-axis acceleration sensor, provides minute-by-minute physical activity data such as estimated metabolic equivalents (METs) and step counts. These measurements can be aggregated to daily estimates; however, their accuracies have not been fully explored in adults under free-living settings.

OBJECTIVE

This study aims to assess the agreement between the TDK Silmee W22 and the research-grade activity monitor, ActiGraph wGT3X-BT, in estimating daily steps and time spent in moderate to vigorous physical activity (MVPA ≥3 METs) in adults under free-living settings.

METHODS

A convenience sample of young to older adults was recruited from communities across several prefectures in Japan. Participants concurrently wore a TDK Silmee W22 on their nondominant wrist and an ActiGraph wGT3X-BT on the left side of the waist during waking hours for 7 consecutive days. Data were aggregated to daily steps and time spent in MVPA (≥1952 vertical axis counts/minute for ActiGraph) for each participant. A valid day was defined as having ≥ 10 hours of accumulated ActiGraph wear time with ≥100 and <50,000 accumulated steps from both devices. Each valid day was classified as either an active day (≥10,000 steps/day or ≥21.4 minutes MVPA per day) or an inactive day. Bland-Altman plots combined with multilevel analysis and κ statistics were used to assess the agreement between physical activity estimates from the devices.

RESULTS

A total of 129 participants (n=66, 51.2% women) aged 23-89 years provided the final dataset of 884 observations (5 to 7 daily observations/participant). The TDK Silmee W22 estimated an overall mean of 6369 (SE 242) steps/day and 40.3 (SE 1.9) minutes/day spent in MVPA. Although Bland-Altman plots suggested no obvious proportional bias, fixed biases were observed; the TDK Silmee W22 estimated -1203 steps/day (95% limits of agreement [LoA] -4202 to 1796) and +5 minutes/day (LoA-23 to 34) spent in MVPA compared with those estimated by the ActiGraph wGT3X-BT. TDK Silmee W22 and ActiGraph wGT3X-BT, respectively, classified 14% and 23.1% as active by daily step counts (κ=0.65, 95% CI 0.59-0.72), and 70.4% and 60.9% as active by daily time spent in MVPA (κ=0.64, 95% CI 0.59-0.69), both indicating moderate agreement.

CONCLUSIONS

TDK Silmee W22 underestimated step counts and overestimated time spent in MVPA compared with the research-grade ActiGraph wGT3X-BT, which may lead to misclassification of active and inactive days. Caution is warranted when using TDK Silmee W22 data over relatively short periods, as discrepancies-particularly when compared with research-grade monitors-may affect feedback or goal setting.

摘要

背景

可穿戴物联网(IoT)设备是远程收集密集纵向数据的强大工具。TDK Silmee W22是一款腕带式可穿戴物联网设备,内置三轴加速度传感器,可提供每分钟的身体活动数据,如估计代谢当量(METs)和步数。这些测量值可以汇总为每日估计值;然而,在自由生活环境下的成年人中,其准确性尚未得到充分探索。

目的

本研究旨在评估TDK Silmee W22与研究级活动监测仪ActiGraph wGT3X - BT在自由生活环境下的成年人中估计每日步数和中度至剧烈身体活动(MVPA≥3 METs)时间方面的一致性。

方法

从日本几个县的社区招募了一个从年轻人到老年人的便利样本。参与者在清醒时间连续7天在非优势手腕上佩戴TDK Silmee W22,在左侧腰部佩戴ActiGraph wGT3X - BT。将数据汇总为每个参与者的每日步数和MVPA(ActiGraph≥1952垂直轴计数/分钟)时间。有效日定义为ActiGraph佩戴时间累计≥10小时,且两个设备的累计步数≥100且<50,000。每个有效日分为活跃日(≥10,000步/天或≥21.4分钟MVPA/天)或非活跃日。使用Bland - Altman图结合多水平分析和κ统计来评估设备身体活动估计值之间的一致性。

结果

共有129名年龄在23 - 89岁的参与者(n = 66,51.2%为女性)提供了884次观察的最终数据集(每位参与者5至7次每日观察)。TDK Silmee W22估计每日步数的总体平均值为6369(标准误242)步/天,MVPA时间为40.3(标准误1.9)分钟/天。虽然Bland - Altman图显示没有明显的比例偏差,但观察到固定偏差;与ActiGraph wGT3X - BT估计值相比,TDK Silmee W22估计MVPA步数少1203步/天(95%一致性界限[LoA] - 4202至1796),时间多5分钟/天(LoA - 23至34)。TDK Silmee W22和ActiGraph wGT3X - BT分别根据每日步数将14%和23.1%分类为活跃(κ = 0.65,95% CI 0.59 - 0.72),根据每日MVPA时间将70.4%和60.9%分类为活跃(κ = 0.64,95% CI 0.59 - 0.69),两者均表明中度一致性。

结论

与研究级ActiGraph wGT3X - BT相比,TDK Silmee W22低估了步数,高估了MVPA时间,这可能导致活跃日和非活跃日的错误分类。在相对较短的时间内使用TDK Silmee W22数据时需谨慎,因为差异(特别是与研究级监测仪相比)可能会影响反馈或目标设定。