Suppr超能文献

使用ORPHE分析技术对2型糖尿病患者进行步态分析的可靠性:一项单中心观察性研究。

Reliability of Gait Analysis Using ORPHE ANALYTICS in Patients with Type 2 Diabetes: A Single-center Observational Study.

作者信息

Matsuda Takaaki, Osaki Yoshinori, Takahashi Hirofumi, Matsuda Erika, Suzuki Yasuhiro, Kojo Kosuke, Murayama Yuki, Sugano Yoko, Iwasaki Hitoshi, Mathis Bryan J, Suzuki Hiroaki, Sekiya Motohiro, Shimano Hitoshi

机构信息

Department of Endocrinology and Metabolism, University of Tsukuba Hospital, Tsukuba, Japan.

Tsukuba Clinical Research & Development Organization (T-CReDO), University of Tsukuba, Tsukuba, Japan.

出版信息

JMA J. 2025 Jul 15;8(3):853-870. doi: 10.31662/jmaj.2024-0422. Epub 2025 Jun 13.

Abstract

INTRODUCTION

People with diabetes tend to show abnormalities in gait parameters, including walking speed and stride length, relative to those without diabetes. While inertial measurement units (IMUs) provide a portable alternative to optical motion capture systems, the reliability of gait analysis is influenced by factors such as walking distance, timing, and examiner differences. However, the impact of these parameters on gait analysis in patients with type 2 diabetes (T2D) remains unclear. This study aimed to evaluate the reliability of ORPHE ANALYTICS, an IMU-based gait analysis system, under varying measurement conditions in patients with T2D.

METHODS

We conducted a single-center observational study (n = 9) to clarify the reliability of ORPHE ANALYTICS, a gait analysis motion sensor system developed by ORPHE Inc., which evaluates more than 15 gait parameters, in patients with T2D. The relative reliability was assessed using intraclass correlation coefficients (ICC): ICC or ICC for intra-rater reliability and ICC for inter-rater reliability based on the differences in distance (10 vs. 30 m), examiners, and timing (morning vs. afternoon).

RESULTS

Intra-rater reliability was excellent (ICC and ICC ≥0.9) for all gait parameters except coefficient of variation of stride duration and lateral displacement. Measurements taken under different conditions of distance and timing exhibited almost good inter-rater reliability (ICC ≥0.75), while measurements by different examiners exhibited moderate to good reliability (ICC ≥0.50). Significant novel differences were observed in lateral sway during the swing phase, medial sway during the stance phase, and foot angle, with random errors (expressed as percentage of minimal detectable change) exceeding 40% under various measurement conditions.

CONCLUSIONS

ORPHE ANALYTICS exhibited good to excellent intra-rater and inter-rater reliability based on differences in distance and timing. However, persistent inter-rater reliability challenges in patients with T2D warrant analysis by a single examiner.

摘要

引言

与非糖尿病患者相比,糖尿病患者往往在步态参数上表现出异常,包括步行速度和步幅长度。虽然惯性测量单元(IMU)为光学运动捕捉系统提供了一种便携式替代方案,但步态分析的可靠性会受到步行距离、时间以及检查者差异等因素的影响。然而,这些参数对2型糖尿病(T2D)患者步态分析的影响仍不明确。本研究旨在评估基于IMU的步态分析系统ORPHE ANALYTICS在T2D患者不同测量条件下的可靠性。

方法

我们进行了一项单中心观察性研究(n = 9),以阐明ORPHE Inc.开发的步态分析运动传感器系统ORPHE ANALYTICS在T2D患者中的可靠性,该系统可评估超过15种步态参数。使用组内相关系数(ICC)评估相对可靠性:基于距离(10米与30米)、检查者以及时间(上午与下午)的差异,分别计算用于评估同一检查者内部可靠性的ICC或ICC以及用于评估不同检查者之间可靠性的ICC。

结果

除步幅持续时间变异系数和横向位移外,所有步态参数的同一检查者内部可靠性均极佳(ICC和ICC≥0.9)。在不同距离和时间条件下进行的测量显示出几乎良好的不同检查者之间的可靠性(ICC≥0.75),而不同检查者进行的测量显示出中等至良好的可靠性(ICC≥0.50)。在摆动期的横向摆动、站立期的内侧摆动和足角方面观察到显著的新差异,在各种测量条件下随机误差(以最小可检测变化的百分比表示)超过40%。

结论

基于距离和时间的差异,ORPHE ANALYTICS表现出良好至极佳的同一检查者内部和不同检查者之间的可靠性。然而,T2D患者中持续存在的不同检查者之间的可靠性挑战需要由单一检查者进行分析。

https://cdn.ncbi.nlm.nih.gov/pmc/blobs/13c4/12328463/2cf740c3842a/2433-3298-8-3-0853-g001.jpg

文献AI研究员

20分钟写一篇综述,助力文献阅读效率提升50倍。

立即体验

用中文搜PubMed

大模型驱动的PubMed中文搜索引擎

马上搜索

文档翻译

学术文献翻译模型,支持多种主流文档格式。

立即体验