Chen Yinghua, Protas Hillary, Luo Ji, Li Shan, Sohankar Javad, Pan Chen-Ray, Ghisays Valentina, Lee Wendy, Wu Teresa, Chen Ding-Geng, Reiman Eric M, Chen Kewei, Su Yi
Banner Alzheimer's Institute Phoenix Arizona USA.
Arizona Alzheimer's Consortium Phoenix Arizona USA.
Alzheimers Dement (Amst). 2025 Aug 25;17(3):e70165. doi: 10.1002/dad2.70165. eCollection 2025 Jul-Sep.
Amyloid positron emission tomography (PET) allows in vivo measurement of amyloid plaque deposition; however, different tracers lead to different results. We test the hypothesis that the variability in amyloid measurements is related to white matter retention, and accounting for this variability can improve agreements.
Data from the Centiloid project was downloaded and processed for four F18 tracer-to-Pittsburgh Compound B (PiB) pairs to obtain mean cortical standardized uptake value ratio (MCSUVR). Three approaches were examined to account for white matter contribution to the MCSUVR. Pearson's correlation was used to assess the between tracer agreements. Steiger's test was used to determine the significance of improvement.
Accounting for white matter signal improves the agreement. The regional spread function partial volume correction (RSF PVC) method was most consistent in achieving statistically significant improvements ( < 0.05) for all four tracer pairs.
Between-tracer agreement of amyloid measure can be improved by accounting for white matter signal. Further investigation is ongoing for additional improvement.
Analyzing head-to-head data for all four common F18-labeled tracers against Pittsburgh Compound B (PiB).Evaluating three different techniques to correct for white matter signal.Steiger's test to determine the significance of improvements.White matter uptake contributes to the between-tracer measurement difference.
淀粉样蛋白正电子发射断层扫描(PET)可在体内测量淀粉样斑块沉积;然而,不同的示踪剂会导致不同的结果。我们检验了以下假设,即淀粉样蛋白测量的变异性与白质保留有关,考虑这种变异性可改善一致性。
下载并处理来自Centiloid项目的数据,用于四对F18示踪剂与匹兹堡化合物B(PiB)的比较,以获得平均皮质标准化摄取值比率(MCSUVR)。研究了三种方法来考虑白质对MCSUVR的贡献。使用Pearson相关性评估示踪剂之间的一致性。使用Steiger检验确定改善的显著性。
考虑白质信号可改善一致性。区域扩散函数部分容积校正(RSF PVC)方法在使所有四对示踪剂均实现具有统计学显著性的改善(<0.05)方面最为一致。
通过考虑白质信号可改善淀粉样蛋白测量的示踪剂间一致性。正在进行进一步研究以实现更多改善。
分析所有四种常见F18标记示踪剂与匹兹堡化合物B(PiB)的直接对比数据。评估三种不同的白质信号校正技术。使用Steiger检验确定改善的显著性。白质摄取导致示踪剂间测量差异。