Suppr超能文献

动态氧评估技术能够确定麻醉对组织的影响。

Dynamic oxygen assessment techniques enable determination of anesthesia's impact on tissue.

作者信息

Clark Megan A, Tavakkoli Armin D, Petusseau Arthur F, Scorzo Augustino V, Kheirollah Alireza, Strawbridge Rendall R, Davis Scott C, Bruza Petr, Pogue Brian W, Gladstone David J, Hoopes P Jack

机构信息

Thayer School of Engineering at Dartmouth College, Hanover, NH, USA.

Geisel School of Medicine at Dartmouth College, Hanover, NH, USA.

出版信息

Sci Rep. 2025 Aug 27;15(1):31611. doi: 10.1038/s41598-025-14428-8.

Abstract

Tissue oxygenation is well understood to impact radiosensitivity, with reports demonstrating a significant effect of breathing condition and anesthesia type on tissue oxygenation levels and radiobiological response. However, the temporal kinetics of intracellular and extracellular oxygenation have never been quantified, on the timescale that may affect radiotherapy studies. C57BL/6 mice were anesthetized using isoflurane at various percentages or ketamine/xylazine (ket/xyl: 100/10 mg/kg) (N = 48). Skin pO was measured using Oxyphor PdG4 and tracked after anesthetization began. Oxyphor data was validated with relative measurements of intracellular oxygen via protoporphyrin IX (PpIX) delayed fluorescence (DF) imaging. Ex vivo localization of both PdG4 Oxyphor and PpIX were quantified. Under all isoflurane anesthesia conditions, leg skin pO levels significantly increased from 12 to 15 mmHg at the start of anesthesia induction (4-6 min) to 24-27 mmHg after 10 min (p < 0.05). Ketamine/xylazine anesthesia led to skin pO maintained at 15-16 mmHg throughout the 10-minute study period (p < 0.01). An increase of pO in mice breathing isoflurane was demonstrated with Oxyphor and PpIX DF, indicating similar intracellular and extracellular oxygenation. These findings demonstrate the importance of routine anesthesia administration, where consistency in the timing between induction and irradiation may be crucial to minimizing variability in radiation response.

摘要

组织氧合对放射敏感性的影响已得到充分理解,有报告表明呼吸状况和麻醉类型对组织氧合水平及放射生物学反应有显著影响。然而,在可能影响放射治疗研究的时间尺度上,细胞内和细胞外氧合的时间动力学从未被量化。使用不同百分比的异氟烷或氯胺酮/赛拉嗪(氯胺酮/赛拉嗪:100/10 mg/kg)对C57BL/6小鼠进行麻醉(N = 48)。使用Oxyphor PdG4测量皮肤pO,并在麻醉开始后进行跟踪。通过原卟啉IX(PpIX)延迟荧光(DF)成像对细胞内氧的相对测量来验证Oxyphor数据。对PdG4 Oxyphor和PpIX的离体定位进行了量化。在所有异氟烷麻醉条件下,腿部皮肤pO水平在麻醉诱导开始时(4 - 6分钟)从12 mmHg显著增加到15 mmHg,10分钟后增加到24 - 27 mmHg(p < 0.05)。氯胺酮/赛拉嗪麻醉导致皮肤pO在整个10分钟研究期间维持在15 - 16 mmHg(p < 0.01)。用Oxyphor和PpIX DF证明了吸入异氟烷的小鼠pO增加,表明细胞内和细胞外氧合相似。这些发现证明了常规麻醉给药的重要性,其中诱导和照射之间时间的一致性对于最小化辐射反应的变异性可能至关重要。

文献检索

告别复杂PubMed语法,用中文像聊天一样搜索,搜遍4000万医学文献。AI智能推荐,让科研检索更轻松。

立即免费搜索

文件翻译

保留排版,准确专业,支持PDF/Word/PPT等文件格式,支持 12+语言互译。

免费翻译文档

深度研究

AI帮你快速写综述,25分钟生成高质量综述,智能提取关键信息,辅助科研写作。

立即免费体验