胎儿磁共振成像中的肺容积分割:超分辨率重建提高了评分者间的可靠性。

Lung volume segmentation in fetal MRI: super-resolution reconstructions improve inter-rater reliability.

作者信息

Payette Kelly, Geiger Julia, Zellner Michael, Steger Céline, Kellenberger Christian J, Tuura Ruth, Kottke Raimund, Jakab Andras

机构信息

Center for MR-Research, University Children's Hospital Zurich, University of Zurich, Zurich, Switzerland.

Neuroscience Center Zurich, University of Zurich, Zurich, Switzerland.

出版信息

Eur Radiol Exp. 2025 Sep 9;9(1):88. doi: 10.1186/s41747-025-00628-4.

Abstract

BACKGROUND

Fetal MRI is increasingly used to investigate fetal lung pathologies, and super-resolution (SR) algorithms could be a powerful clinical tool for this assessment. Our goal was to investigate whether SR reconstructions result in an improved agreement in lung volume measurements determined by different raters, also known as inter-rater reliability.

MATERIALS AND METHODS

In this single-center retrospective study, fetal lung volumes calculated from both SR reconstructions and the original images were analyzed. Three radiologists manually segmented the fetal lungs and rated the image quality of all images and reconstructions. Fetal lung volumes were calculated, and the coefficient of variation (CV) was determined for each set of images. Bland-Altman plots were generated, and intraclass correlation coefficients (ICCs) were calculated. A one-sided paired Wilcoxon test was used to compare the fetal lung volume CVs, and a two-sided paired t-test was used to compare the lung volumes. The quality ratings were compared using a two-sided paired Wilcoxon test.

RESULTS

A total of 98 fetal scans with gestational ages from 19 to 37 weeks were evaluated. There was a significantly lower CV in the lung volumes segmented from the SR reconstructions (p < 0.001), and the ICCs of the reconstructions were higher than those determined from the original images. Bland-Altman plots demonstrated better agreement in the SR reconstruction lung volumes. No significant differences in quality ratings or lung volumes were found.

CONCLUSION

SR reconstructions of the fetal lungs in MRI enabled better inter-rater reliability of fetal lung volume assessment.

RELEVANCE STATEMENT

SR reconstructions of the fetal body, obtained through fetal MRI, can be a valuable tool for improving the inter-rater reliability of fetal lung volume measurements, a crucial clinical biomarker for assessing fetal development and predicting pregnancy outcomes.

KEY POINTS

Deformable slice-to-volume reconstructions of fetal body MRI could be a valuable clinical tool. Quantitative advantages of fetal body MRI reconstructions need to be proven. Fetal body MRI reconstructions improved inter-rater reliability in lung volume measurements.

摘要

背景

胎儿磁共振成像(MRI)越来越多地用于研究胎儿肺部病变,超分辨率(SR)算法可能是用于该评估的强大临床工具。我们的目标是研究SR重建是否能提高不同评估者所确定的肺容积测量结果的一致性,即评分者间可靠性。

材料与方法

在这项单中心回顾性研究中,分析了从SR重建和原始图像计算得出的胎儿肺容积。三名放射科医生手动分割胎儿肺部,并对所有图像和重建图像的质量进行评分。计算胎儿肺容积,并确定每组图像的变异系数(CV)。生成布兰德-奥特曼图,并计算组内相关系数(ICC)。使用单侧配对威尔科克森检验比较胎儿肺容积CV,使用双侧配对t检验比较肺容积。使用双侧配对威尔科克森检验比较质量评分。

结果

共评估了98例孕周为19至37周的胎儿扫描。SR重建分割出的肺容积CV显著更低(p < 0.001),重建图像的ICC高于从原始图像确定的ICC。布兰德-奥特曼图显示SR重建肺容积的一致性更好。在质量评分或肺容积方面未发现显著差异。

结论

MRI中胎儿肺部的SR重建使胎儿肺容积评估的评分者间可靠性更高。

相关性声明

通过胎儿MRI获得的胎儿身体SR重建可以是提高胎儿肺容积测量评分者间可靠性的有价值工具,胎儿肺容积是评估胎儿发育和预测妊娠结局的关键临床生物标志物。

关键点

胎儿身体MRI的可变形切片到容积重建可能是一种有价值的临床工具。胎儿身体MRI重建的定量优势需要得到证实。胎儿身体MRI重建提高了肺容积测量的评分者间可靠性。