Suppr超能文献

根管冲洗剂对镍钛旋转器械循环疲劳抗力的影响:一项系统评价

Effect of Endodontic Irrigants on the Cyclic Fatigue Resistance of Nickel-Titanium Rotary Instruments: A Systematic Review.

作者信息

Karaś Bartłomiej, Kotela Agnieszka, Laszczyńska Marzena, Majchrzak Zuzanna, Trafalski Mateusz, Matys Jacek, Dobrzyński Maciej

机构信息

Medical Center of Innovation, Wroclaw Medical University, Krakowska 26, 50-425 Wroclaw, Poland.

Dental Surgery Department, Wroclaw Medical University, Krakowska 26, 50-425 Wroclaw, Poland.

出版信息

Materials (Basel). 2025 Aug 29;18(17):4056. doi: 10.3390/ma18174056.

Abstract

Instrument fracture during endodontic treatment significantly compromises treatment outcomes, with sodium hypochlorite (NaOCl) and other irrigants potentially affecting the cyclic fatigue resistance of nickel-titanium (NiTi) rotary files. This systematic review evaluated the impact of endodontic irrigants on NiTi instrument durability. A comprehensive literature search was conducted across PubMed, Scopus, Web of Science, Embase, Cochrane Library, and WorldCat databases through June 2025, following PRISMA guidelines. Studies investigating cyclic fatigue resistance of NiTi rotary instruments exposed to various irrigants were included. Twenty-seven in vitro studies met the inclusion criteria, involving instruments across multiple file systems and irrigant solutions. The review revealed that NaOCl, particularly at concentrations ≥5% and elevated temperatures, significantly reduced cyclic fatigue resistance in most studies, with scanning electron microscopy confirming surface corrosion and microcrack formation. Heat-treated NiTi alloys demonstrated superior fatigue resistance compared to conventional austenitic alloys. Short-term NaOCl exposure (1-5 min) showed minimal impact, while prolonged exposure combined with autoclave sterilization produced cumulative weakening effects. Alternative irrigants such as EDTA and chlorhexidine showed more neutral effects on instrument integrity. These findings suggest that irrigant selection and exposure protocols significantly influence NiTi instrument longevity, with implications for clinical endodontic practice and instrument safety protocols.

摘要

根管治疗期间器械折断会显著影响治疗效果,次氯酸钠(NaOCl)和其他冲洗剂可能会影响镍钛(NiTi)旋转锉的循环疲劳抗力。本系统评价评估了根管冲洗剂对NiTi器械耐久性的影响。按照PRISMA指南,截至2025年6月,在PubMed、Scopus、Web of Science、Embase、Cochrane图书馆和WorldCat数据库中进行了全面的文献检索。纳入了研究暴露于各种冲洗剂下的NiTi旋转器械循环疲劳抗力的研究。27项体外研究符合纳入标准,涉及多个锉系统和冲洗剂溶液的器械。该评价显示,在大多数研究中,NaOCl,尤其是浓度≥5%且温度升高时,会显著降低循环疲劳抗力,扫描电子显微镜证实了表面腐蚀和微裂纹形成。与传统奥氏体合金相比,热处理的NiTi合金表现出更好的抗疲劳性。短期暴露于NaOCl(1 - 5分钟)影响最小,而长时间暴露并结合高压灭菌会产生累积削弱作用。乙二胺四乙酸(EDTA)和氯己定等替代冲洗剂对器械完整性的影响更为中性。这些发现表明,冲洗剂的选择和暴露方案会显著影响NiTi器械的使用寿命,对临床根管治疗实践和器械安全方案具有重要意义。

https://cdn.ncbi.nlm.nih.gov/pmc/blobs/2995/12429284/54c8c403ae0f/materials-18-04056-g001.jpg

文献检索

告别复杂PubMed语法,用中文像聊天一样搜索,搜遍4000万医学文献。AI智能推荐,让科研检索更轻松。

立即免费搜索

文件翻译

保留排版,准确专业,支持PDF/Word/PPT等文件格式,支持 12+语言互译。

免费翻译文档

深度研究

AI帮你快速写综述,25分钟生成高质量综述,智能提取关键信息,辅助科研写作。

立即免费体验