Demir Fadime, Demir Mustafa, Karaçavuş Seyhan, Yeşilyurt Muhammet İkbal, Laçin Mahmut Burak
Department of Nuclear Medicine, Kayseri SUAM, Kayseri, Turkey.
Department of Nephrology, Kayseri SUAM, Kayseri, Turkey.
Int Urol Nephrol. 2025 Sep 14. doi: 10.1007/s11255-025-04780-z.
The aim is to investigate the correlation between renal maximum standardized uptake value (SUVmax), mean standardized uptake value (SUVmean), molecular kidney volume (MKV), and total kidney uptake (TKU), which are indicators of the PSMA kidney uptake pattern in Ga-PSMA-11 PET/CT imaging and kidney function tests. We secondarily aim to investigate how accurately renal parameters obtained from Ga-PSMA-11 PET/CT can provide information about the patient's kidney functions.
The study included 196 patients with prostate cancer who underwent Ga-PSMA-11 PET/CT imaging for staging purposes. Semiquantitative analyses were performed on the kidneys in the PET/CT images, and renal SUVmax, SUVmean, MKV, TKU values, as well as anatomical kidney volume (CT-KV) from CT imaging, were calculated. The patients' concurrent laboratory results, including eGFR, BUN, and creatinine levels, were recorded. Statistical analyses were performed using the SPSS 22 software. The Spearman test was used to determine the correlation between the parameters. The ANOVA test was used for intergroup comparisons, and the Tamhane test was used for post-hoc analyses.
When comparing eGFR, BUN, and creatinine values with PET/CT renal parameters, a significant correlation was found between eGFR and MKV (r = 0.397), TKU (r = 0.271), and CT-KV (r = 0.216). Similar correlations were also observed for BUN and creatinine. When patients were grouped based on eGFR values, Group 1 (eGFR > 90; normal) included 75 patients, Group 2 (eGFR: 89-60; mild reduction) included 98 patients, and Group 3 (eGFR: 59-30; moderate reduction) included 21 patients. Significant differences were observed between the groups in terms of TKU, MKV, and CT-KV. In post-hoc analyses, the most significant parameter was MKV.
Ga-PSMA-11 PET/CT-derived renal parameters, particularly the molecular kidney volume (MKV), exhibit a significant positive correlation with renal function and demonstrate a significant decrease in patients with renal dysfunction compared to those with normal renal function.
本研究旨在探讨肾最大标准化摄取值(SUVmax)、平均标准化摄取值(SUVmean)、分子肾体积(MKV)和总肾摄取量(TKU)之间的相关性,这些指标反映了镓-PSMA-11 PET/CT成像中PSMA肾摄取模式及肾功能测试情况。其次,我们旨在研究从镓-PSMA-11 PET/CT获得的肾脏参数能多准确地提供患者肾功能信息。
本研究纳入196例因分期目的接受镓-PSMA-11 PET/CT成像的前列腺癌患者。对PET/CT图像中的肾脏进行半定量分析,计算肾SUVmax、SUVmean、MKV、TKU值以及CT成像中的解剖学肾体积(CT-KV)。记录患者同时期的实验室检查结果,包括估算肾小球滤过率(eGFR)、血尿素氮(BUN)和肌酐水平。使用SPSS 22软件进行统计分析。采用Spearman检验确定参数之间的相关性。采用方差分析进行组间比较,采用Tamhane检验进行事后分析。
将eGFR、BUN和肌酐值与PET/CT肾脏参数进行比较时,发现eGFR与MKV(r = 0.397)、TKU(r = 0.271)和CT-KV(r = 0.216)之间存在显著相关性。BUN和肌酐也观察到类似的相关性。根据eGFR值对患者进行分组,第1组(eGFR>90;正常)包括75例患者,第2组(eGFR:89 - 60;轻度降低)包括98例患者,第3组(eGFR:59 - 30;中度降低)包括21例患者。各组之间在TKU、MKV和CT-KV方面存在显著差异。在事后分析中,最显著的参数是MKV。
镓-PSMA-11 PET/CT衍生的肾脏参数,特别是分子肾体积(MKV),与肾功能呈显著正相关,与肾功能正常的患者相比,肾功能不全患者的该参数显著降低。