A simple, direct radioimmunoassay for cortisol in human serum and plasma is described. An antiserum, raised in sheep to a cortisol-3-(O-carboxymethyl)oxime/bovine serum albumin conjugate, is coupled to microcellulose. No extraction is required because plasma samples and standards are incubated with the antiserum and an 125I radioligand in a low-pH buffer, which denatures cortisol-binding globulins. The assay satisfies accepted validation criteria. In addition, results from the radioimmunoassay compare well with those obtained by a gas chromatographic-mass spectrometric technique (r = 0.968; FRIA = 0.97 FGCMS + 2.0 nmol/L). The latter procedure features the very high intrinsic specificity obtained by selected ion monitoring at high mass-spectrometric resolution (M/deltaM = 8500) with a Varian MAT-731 instrument. The simplicity of the radioimmunoassay procedure, with use of reagents prepared "in house," makes this a very practical and economical assay for use in the medium or large endocrine laboratory.
本文描述了一种用于人血清和血浆中皮质醇的简单、直接的放射免疫测定法。用皮质醇-3-(O-羧甲基)肟/牛血清白蛋白偶联物免疫绵羊制备的抗血清与微晶纤维素偶联。由于血浆样品和标准品在低pH缓冲液中与抗血清和125I放射性配体一起孵育,使皮质醇结合球蛋白变性,因此无需萃取。该测定法符合公认的验证标准。此外,放射免疫测定法的结果与气相色谱-质谱技术获得的结果比较良好(r = 0.968;放射免疫分析 = 0.97×气相色谱-质谱 + 2.0 nmol/L)。后一种方法的特点是使用Varian MAT-731仪器在高质谱分辨率(M/ΔM = 8500)下通过选择离子监测获得非常高的内在特异性。放射免疫测定法操作简单,使用“自制”试剂,使其成为中大型内分泌实验室非常实用且经济的测定方法。