Jatlow P, Bush W, Hochster H
Clin Chem. 1979 May;25(5):777-9.
We describe an analysis for propranolol in plasma, with use of reversed-phase "high-pressure" liquid chromatography and fluorescence detection. Pronethalol is used as the internal standard. The procedure, which involves extraction into an organic solvent, evaporation, and clean-up by micro-scale back extraction from hexane into an aqueous phase, is specific and sensitive. The detection limit is less than 6 microgram/L (2.3 X 10(-8) mol/L). Within-day and between-day coefficients of variation are 1.8 and 4.4%, respectively. Commonly used drugs, including procainamide, N-acetylprocainamide, and quinidine, do not interfere.
我们描述了一种利用反相“高压”液相色谱法和荧光检测法分析血浆中普萘洛尔的方法。丙萘洛尔用作内标。该方法包括用有机溶剂萃取、蒸发以及通过从己烷到水相的微量反萃取进行净化,具有特异性和灵敏性。检测限低于6微克/升(2.3×10⁻⁸摩尔/升)。日内和日间变异系数分别为1.8%和4.4%。常用药物,包括普鲁卡因胺、N-乙酰普鲁卡因胺和奎尼丁,均无干扰。