van Brocklin M D, Yolton R L
J Am Optom Assoc. 1979 Feb;50(2):203-7.
VERs were recorded from 30 normal and two multiple sclerosis (MS) subjects using a steady state checkerboard stimulus. The normal subjects produced a mean OU latency of 90.8 msec with a mean absolute interocular latency difference of 3.2 msec. Latencies from the MS patients were up to 13 standard deviations longer than the latencies from the normal subjects.
使用稳态棋盘格刺激,从30名正常受试者和2名多发性硬化症(MS)患者中记录视觉诱发电位(VERs)。正常受试者的双眼平均潜伏期为90.8毫秒,双眼间平均绝对潜伏期差异为3.2毫秒。MS患者的潜伏期比正常受试者的潜伏期长多达13个标准差。