Suppr超能文献

使用圣犹达医疗假体进行心脏瓣膜置换术——初步临床结果——

Heart valve replacement with the St. Jude medical prosthesis -- first clinical results --.

作者信息

Hehrlein F W, Gottwik M G, Schlepper M, Fraedrich G

出版信息

Thorac Cardiovasc Surg. 1979 Jun;27(3):187-9. doi: 10.1055/s-0028-1096241.

Abstract

Starting in February 1978 52 St. Jude Medical Prostheses have been implanted in 47 patients (age 13--73 years) in aortic, mitral and tricuspid positions. Perioperative death occurred in 3 cases. Post mortem examination of these patients showed unimpaired valvular function. There were no other complications in an accumulated total valve time of approximately 300 months. Prior to surgery and post-operatively, several hemolytic parameters were analyzed. There was only a mild elevation in Serum LDH (285 +/- 10 iV/L). Fifteen patients underwent recatheterization 3 months postoperatively. The mitral valves did not reveal an enddiastolic gradient at rest, while the aortic valves had a peak to peak gradient of 8 +/- 2.1 mmHg. A standardized stress consisting of an infusion of isoproterenol was used. The results were compared to results obtained in patients with Björk-Shiley prostheses under identical conditions and did not show a significant difference. The preliminary hemodynamic findings correlate with preceding in vitro results and preclinical data, and the first clinical experience is promising.

摘要

从1978年2月开始,已将52个圣犹达医疗人工瓣膜植入47例患者(年龄13 - 73岁)的主动脉、二尖瓣和三尖瓣位置。围手术期死亡3例。对这些患者的尸检显示瓣膜功能未受损。在累计总瓣膜使用时间约300个月的情况下,未出现其他并发症。术前和术后分析了多项溶血参数。血清乳酸脱氢酶仅轻度升高(285±10 iV/L)。15例患者在术后3个月接受了再次导管检查。二尖瓣静息时舒张末期无压力阶差,而主动脉瓣峰 - 峰压力阶差为8±2.1 mmHg。使用了由异丙肾上腺素输注组成的标准化应激试验。将结果与在相同条件下使用 Björk-Shiley 人工瓣膜的患者所获得的结果进行比较,未显示出显著差异。初步的血流动力学结果与之前的体外研究结果和临床前数据相关,且首次临床经验很有前景。

文献检索

告别复杂PubMed语法,用中文像聊天一样搜索,搜遍4000万医学文献。AI智能推荐,让科研检索更轻松。

立即免费搜索

文件翻译

保留排版,准确专业,支持PDF/Word/PPT等文件格式,支持 12+语言互译。

免费翻译文档

深度研究

AI帮你快速写综述,25分钟生成高质量综述,智能提取关键信息,辅助科研写作。

立即免费体验