The need for a device to sample large areas that are lightly contaminated with microorganisms motivated the development of the vacuum probe. The intended use of the instrument is to sample clean surfaces in laminar flow clean rooms, but the device could be used for sampling surfaces in other clean environments. Such a device was designed, fabricated, and tested at Sandia Laboratories, Albuquerque, N.M. In these tests, the vacuum probe removed a mean of 89% and assayed a mean of 67% of bacterial spores, approximately 1 mum in length, settled on smooth surfaces which were free from viscous films.
对一种用于对受微生物轻度污染的大面积区域进行采样的设备的需求推动了真空探针的开发。该仪器的预期用途是对层流洁净室中的清洁表面进行采样,但该设备也可用于对其他洁净环境中的表面进行采样。这样一种设备是在新墨西哥州阿尔伯克基的桑迪亚实验室设计、制造和测试的。在这些测试中,真空探针平均去除了89%的细菌孢子,并对沉降在无粘性薄膜的光滑表面上、长度约为1微米的细菌孢子进行了平均67%的检测。