Suppr超能文献

梅尔泰克多点血液透析器

Meltec Multipoint haemodialyser.

作者信息

Von Hartitzsch B, Hoenich N A

出版信息

Br Med J. 1972 Jan 22;1(5794):237-9. doi: 10.1136/bmj.1.5794.237.

Abstract

The 0.61 m(2) Meltec Multipoint dialyser has a performance 25% better than the standard Kiil at clinically important blood flows despite its smaller surface area. With low priming and uptake volumes, adequate ultrafiltration, and a negligible residual blood volume, it is compact and can be assembled by one person. It should replace the Kiil as the standard against which new dialysers are measured.

摘要

0.61平方米的Meltec多点透析器,尽管其表面积较小,但在具有临床意义的血流量下,性能比标准基尔透析器高出25%。它预充量和超滤量低,超滤充分,残余血量可忽略不计,结构紧凑,一人即可组装。它应取代基尔透析器,成为衡量新型透析器的标准。

相似文献

1
Meltec Multipoint haemodialyser.梅尔泰克多点血液透析器
Br Med J. 1972 Jan 22;1(5794):237-9. doi: 10.1136/bmj.1.5794.237.
2
Disposable membrane insert for the Kiil dialyser.用于基尔透析器的一次性膜插入件。
Br Med J. 1972 Jan 22;1(5794):235-6. doi: 10.1136/bmj.1.5794.235.
4
Effect of membrane grain orientation on in vitro performance of a Kiil dialyzer.
Kidney Int. 1973 Mar;3(3):186-9. doi: 10.1038/ki.1973.27.
5
Clinical evaluation of a disposable artificial kidney.一次性人工肾的临床评估
Br Med J. 1969 Aug 23;3(5668):447-9. doi: 10.1136/bmj.3.5668.447.
8
Improved phosphate clearances with polycarbonate membranes.聚碳酸酯膜可改善磷酸盐清除率。
Clin Exp Dial Apheresis. 1982;6(4):211-22. doi: 10.3109/08860228209049854.

引用本文的文献

1
Disposable membrane insert for the Kiil dialyser.用于基尔透析器的一次性膜插入件。
Br Med J. 1972 Jan 22;1(5794):235-6. doi: 10.1136/bmj.1.5794.235.

本文引用的文献

1
Dialyser gaskets.透析器垫圈。
Br Med J. 1970 Jul 25;3(5716):226-7. doi: 10.1136/bmj.3.5716.226-b.
2
Disposable membrane insert for the Kiil dialyser.用于基尔透析器的一次性膜插入件。
Br Med J. 1972 Jan 22;1(5794):235-6. doi: 10.1136/bmj.1.5794.235.