J Clin Pathol. 1972 Jun;25(6):508-11. doi: 10.1136/jcp.25.6.508.
Polyacrylamide gels constitute a generally better matrix for routine electrophoresis of serum proteins than other media commonly employed, but the immunoglobulin fractions of the largest size may not migrate into gels in which the acrylamide concentration exceeds 5%. To facilitate adequate separation, slabs containing a semi-solid layer were prepared from discontinuous gels consisting of 2 to 8% acrylamide. Serum samples were subjected to electrophoresis, under carefully controlled conditions at pH 9.0, by means of a pulsed constant power supply. The method provided a rapid, reproducible, and relatively simple technique for the study of human serum proteins, either by electrophoresis or by immunoelectrophoresis, and for differentiation of serum samples from various animal species.
对于血清蛋白的常规电泳而言,聚丙烯酰胺凝胶通常比其他常用介质构成更好的基质,但最大尺寸的免疫球蛋白组分可能不会迁移到丙烯酰胺浓度超过5%的凝胶中。为便于充分分离,由2%至8%丙烯酰胺组成的不连续凝胶制备了含有半固体层的平板。血清样品在pH 9.0的精心控制条件下,通过脉冲恒电源进行电泳。该方法为通过电泳或免疫电泳研究人血清蛋白以及区分各种动物物种的血清样品提供了一种快速、可重复且相对简单的技术。