Biggs D A
J Assoc Off Anal Chem. 1979 Nov;62(6):1202-7.
Thirty-eight milks (including homogenized and unhomogenized herd milks, individual cow milks, and packaged milks) were pre-analyzed by accepted standard methods and then analyzed in duplicate with a Multispec instrument on 2 different days. For the combined data, mean differences between duplicates were 0.01% or less within days and 0.025% or less between days. Standard deviations of difference between duplicates were 0.02% or less. Overall mean differences between Multispec and standard results were 0.02% or less with standard deviations of difference of 0.041%, but means for protein in packaged milks were 0.038% lower and means for lactose in individual cow milks were 0.04% higher than standards. Standard deviations of difference for fat were lower (0.016%) than average for packaged milks and higher (0.06%) than average for individual cow milks. Differences between Multispec results for homogenized and unhomogenized samples of the same herd milks were small, averaging 0.013% for fat, 0.005% for protein, and 0.011% for lactose. Regression equations for the combined data gave standard errors of estimate of about the same magnitude as the standard deviations of difference. Single calibrations would give good estimates for all of the types of milk analyzed, but for best accuracy the instrument should be calibrated with the type of milk to be analyzed.
38份牛奶样本(包括均质和非均质的 herd 牛奶、个体奶牛的牛奶以及包装牛奶)先用公认的标准方法进行预分析,然后在2个不同日期用 Multispec 仪器进行双份分析。对于合并后的数据,同一天内双份测定的平均差异在0.01%以内,不同日期之间的平均差异在0.025%以内。双份测定差异的标准差在0.02%以内。Multispec 测定结果与标准结果的总体平均差异在0.02%以内,差异的标准差为0.041%,但包装牛奶中蛋白质的平均值比标准值低0.038%,个体奶牛牛奶中乳糖的平均值比标准值高0.04%。脂肪差异的标准差对于包装牛奶低于平均值(0.016%),对于个体奶牛牛奶高于平均值(0.06%)。同一 herd 牛奶的均质和非均质样本的 Multispec 测定结果差异很小,脂肪平均差异为0.013%,蛋白质为0.005%,乳糖为0.011%。合并数据的回归方程给出的估计标准误差与差异的标准差大小大致相同。单次校准对于所有分析的牛奶类型都能给出较好的估计,但为了获得最佳准确性,仪器应以要分析的牛奶类型进行校准。