Abstract

A mathematical analysis of fluid exchange during hemodialysis therapy was performed in order to determine which factors affect the circulating blood volume, and hence the circulatory stability. It was found that both fluid removal and also the fall of plasma osmolality during the passage of blood through the dialyzer can affect the circulating blood colume profoundly. The later was found to accelerate the decrease of circulating blood volume by an indirect action on capillary refilling. Some treatment systems such as those involving recirculation or ultrafiltration were found to show a small fall in osmolality with a correspondingly small fall in blood pressure. This result seems to be compatible with clinical experiences reported earlier and may explain why some methods of treatment are accompanied by stable circulatory function in spite of rapid removal of large amounts of fluid.

摘要

为了确定哪些因素会影响循环血量,进而影响循环稳定性,对血液透析治疗期间的液体交换进行了数学分析。结果发现,血液通过透析器时的液体清除以及血浆渗透压的下降都会对循环血量产生深远影响。后者被发现通过对毛细血管再充盈的间接作用加速循环血量的减少。一些治疗系统,如涉及再循环或超滤的系统,被发现渗透压有小幅下降,血压也相应小幅下降。这一结果似乎与早期报道的临床经验相符,并且可以解释为什么尽管快速清除大量液体,但某些治疗方法仍伴随着稳定的循环功能。